Vizi Roller Beam 2R ©2013 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
Table of Contents Unpacking......................................................................3 Introduction....................................................................3 Customer Support......................................................................3 Safety Precautions......................................................................4 Features.........................................................................5 Handling Precautions..................................................
Vizi Roller Beam 2R Safety Precautions For Your Own Personal Safety, Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit! • To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture • Do not spill water or other liquids into or on to your unit. • Be sure that the local power outlet match that of the required volt age for your unit. • Do not attempt to operate this unit if the power cord has been frayed or broken.
Vizi Roller Beam 2R General Instructions To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference. Vizi Roller Beam 2R Handling Precautions Caution! There are no user serviceable parts inside this unit.
Vizi Roller Beam 2R Mounting When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without any deformation. When installing the unit must be secured with a secondary safety attachment, e.g. an appropriate safety cable. Never stand directly below the unit when mounting, removing, or servicing the unit.
Vizi Roller Beam 2R Controls and Functions Vizi Roller Beam 2R Controls and Functions 1. Cone Barrel Mirror - This is a highly reflective surface mirror specifically designed to optimize and enhance beam output. Never use glass cleaner that contain ammonia to clean the surface of the mirror (such as Windex). 2. Digital Display - This display shows the menu and operating functions that you can choose from. 4 1 3.
Vizi Roller Beam 2R Controls and Functions 12. XLR DMX Input Jack - This jack is used to receive an incoming DMX signal or Master/Slave signal. 13. XLR Output Jack - This jack is used to transmit the incoming DMX signal to another DMX fixture, or transmit a Master/Slave signal to the next Vizi Roller Beam 2R in the chain. For best results in DMX or Master/Slave mode terminate this jack if it is the last unit in the chain. See “Line Termination” on page 14. 14.
REMOTE CONTROL INPUT SOUND INPUT OUTPUT REMOTE CONTROL INPUT SOUND INPUT Vizi Roller Beam 2R OUTPUT SOUND Set Up INPUT OUTPUT Vizi Roller Beam 2R remember that DMX cable must be daisy chained and cannot be split. POWER REMOTE CONTROL INPUT POWER Set Up 5-Pin XLR DMX Connectors. Some manufactures use 5-pin DMX- 512 data cables for DATA transmission in place of 3-pin. 5-pin DMX fixtures may be implemented in a 3-pin DMX line.
Function Vizi Roller Beam 2R Set Dmx Address A001~AXXX DMX address setting Dmx Value PAN…… DMX value display Slave Mode Slave1,Slave2,Slave3 Slave setting Auto Program Master / Alone Auto program Sound Control Master / Alone Information Time Information Lamp Control Temperature Info XXXX(Hours) Power on running time Total Run Time XXXX(Hours) Fixture running time XXXX(Hours) Fixture Last times clear Lamp Hours XXXX(Hours) Lamp running time Lamp Off Time XXXX(Minute) Lamp o
Vizi Roller Beam 2R System Menu Slave Mode - This function lets you designate the unit as the slave in a Master-Slave configuration. 1. Access the main menu, and press the UP or DOWN buttons so that “Function” is highlighted, then press ENTER. 2. Press the UP or DOWN buttons until “Slave Mode” is displayed, and press ENTER. 3. Either Slave 1, Slave 2, or Slave 3 will be displayed. Press ENTER to select either of the three, or press MODE/ESC button to exit.
Vizi Roller Beam 2R System Menu 1. Press the MODE/ESC button to access the main menu. Press the UP or DOWN buttons so that “Information” is highlighted, then press ENTER. 2. Press the UP or DOWN buttons until “Time Information” is displayed, press ENTER. 3. Press UP or DOWN buttons, until “Last Run Time” is displayed, and press ENTER. 4. “XXXX” will now be displayed. “XXXX” represents the last running time. 5. Press ENTER or press MODE/ESC to exit.
Vizi Roller Beam 2R System Menu the UP or DOWN buttons so that “Information” is highlighted, then press ENTER. 2. Press the UP or DOWN buttons until “Time Information” is displayed, press ENTER. 3. Press UP or DOWN buttons, until “Lamp Time Password” is displayed, and press ENTER. 4. The “Lamp Time Password” is 038. 5. Press ENTER or press MODE/ESC to exit. Clean Lamp Time - This will allow you to clear the lamp time running time. Please clear the lamp running time every time you replace the lamp.
Vizi Roller Beam 2R System Menu 2. Press the UP or DOWN buttons until “Automatic On” is displayed, press ENTER. 3. Either “Off” or “On” will be displayed, use the UP and DOWN buttons to toggle between. 4. Press ENTER to confirm your selection or press MODE/ESC to exit. Lamp on via external controller - With this function you can select if you want to switch the lamp on via an external controller. This is used in conjuction with Internal Programs DMX channel, DMX values 40-59. 1.
Vizi Roller Beam 2R System Menu PERSONALITY Time Information Address via DMX - With this function you can adjust the DMX address via external controller. 1. Press the MODE/ESC button to access the main menu. Press the UP or DOWN buttons so that “Personality” is highlighted, then press ENTER. 2. Press the UP or DOWN buttons until “Status Setting” is displayed, press ENTER. 3. Press UP or DOWN buttons, until “Address via DMX” is displayed, and press ENTER. 4.
Vizi Roller Beam 2R System Menu 4. “70%” will be displayed, use the UP and DOWN buttons to adjust the sensitivity between 0%-99%. 5. Press ENTER to confirm your selection or press MODE/ESC to exit. Hibernation - With this function the lamp and step motors will power off if there is no DMX signal within 15 mins (factory defualt). Once it receives a DMX signal, the fixture will reset itself. 1. Press the MODE/ESC button to access the main menu.
Vizi Roller Beam 2R System Menu 2-59 minutes. Use this function to adjust the time. 1. Press the MODE/ESC button to access the main menu. Press the UP or DOWN buttons so that “Personality” is highlighted, then press ENTER. 2. Press the UP or DOWN buttons until “Display Setting” is displayed, press ENTER. 3. Press UP or DOWN buttons, until “Shutoff Time” is displayed, and press ENTER. 4.
Vizi Roller Beam 2R System Menu 2. Press the UP or DOWN buttons until “Reset Default” is displayed, press ENTER. 3. Either “Off” or “On” will be displayed, use the UP and DOWN buttons to toggle between. 4. Press ENTER to confirm your selection or press MODE/ESC to exit. RESET FUNCTION Reset All - With this function you can all the motors. 1. Press the MODE/ESC button to access the main menu. Press the UP or DOWN buttons so that “Reset Function” is highlighted, then press ENTER.
Vizi Roller Beam 2R System Menu Vizi Roller Beam 2R System Menu 2. Press the UP or DOWN buttons until “Test Channel” is displayed, press ENTER. UP or DOWN buttons so that “User Mode Set” is highlighted, then press ENTER. 3. Use the UP or DOWN buttons to scroll through the various channels. 2. Press the UP or DOWN buttons until “User Mode” is displayed, press ENTER. 4. Press ENTER or press MODE/ESC to exit. 3. Use the UP or DOWN buttons to scroll through the 3 DMX Channel Modes.
Vizi Roller Beam 2R System Menu Rec Controller - The Vizi Roller Beam 2R features an integrated DMX recorder. Preprogrammed scenes can be transmitted to the fixture via any DMX compliant controller. This function allows those scenes to be stored in to the fixture’s built-in memory and then subsequently used to create the user-defined programs. Vizi Roller Beam 2R Error Codes When power is applied, the unit will automatically enter a “reset/test” mode.
Vizi Roller Beam 2R Error Codes missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB). 06Er – FIXED GOBOS error: This message will appear after a fixture reset, if the magneticindexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).
Vizi Roller Beam 2R Operation DOWN buttons select “Alone” and press ENTER. Master-Slave Operation (Sound Active or Auto Program): This function will allow you to link up to 16 units together and operate without a controller. The units can run a built-in program or run in sound actiive mode. In Master-Slave operation one unit will act as the controlling unit and the others will react to the controlling units programs. Any unit can act as a Master or as a Slave. 1.
Vizi Roller Beam 2R Channel 4 5 Value 96 - 103 104 - 111 112 - 119 120 - 126 127 - 133 134 - 140 141 - 147 148 - 154 155 - 161 162 - 168 169 - 175 176 - 182 183 - 189 190 - 196 197 - 203 204 - 210 211 - 217 218 - 255 0 - 127 128 - 189 190 - 193 194 - 255 6 0 - 31 32 - 127 128 - 135 136 - 143 144 - 151 152 - 159 11 Channel DMX Mode Function GOBOS CONT.
Vizi Roller Beam 2R Channel 10 11 Value 236 - 245 246 - 255 0 - 19 20 - 29 30 - 39 40 - 59 60 - 79 80 - 84 85 - 87 88 - 90 91 - 93 94 - 96 97 - 99 100 - 119 120 - 139 140 - 159 160 - 179 180 - 199 200 - 219 220 - 239 240 - 255 11 Channel DMX Mode Function PAN/TILT MOVEMENT SPEED BLACKOUT BY WHEEL CHANGING NO FUNCTION LAMP ON/OFF, RESET & PROGRAMS COLOR CHANGE NORMAL COLOR CHANGE TO ANY POSITION LAMP ON/OFF, RESET & PROGRAMS COLOR & GOBO CHANGE TO ANY POSITION LAMP ON LAMP OFF ALL MOTOR RESET SC
Vizi Roller Beam 2R Channel 6 7 Value 64 - 71 72 - 79 80 - 87 88 - 95 96 - 103 104 - 111 112 - 119 120 - 126 127 - 133 134 - 140 141 - 147 148 - 154 155 - 161 162 - 168 169 - 175 176 - 182 183 - 189 190 - 196 197 - 203 204 - 210 211 - 217 218 - 255 0 - 127 128 - 189 190 - 193 194 - 255 8 0 - 31 32 - 127 13 Channel DMX Mode Function GOBOS CONT.
Vizi Roller Beam 2R Channel 11 12 13 Value 0 - 255 0 - 225 226 - 235 236 - 245 246 - 255 0 - 19 20 - 29 30 - 39 40 - 59 60 - 79 80 - 84 85 - 87 88 - 90 91 - 93 94 - 96 97 - 99 100 - 119 120 - 139 140 - 159 160 - 179 180 - 199 200 - 219 220 - 239 240 - 255 13 Channel DMX Mode Function DIMMER INTENSITY 0% - 100% PAN/TILT MOVEMENT SPEED MAX TO MIN.
Vizi Roller Beam 2R Channel 7 8 9 Value 48 - 55 56 - 63 64 - 71 72 - 79 80 - 87 88 - 95 96 - 103 104 - 111 112 - 119 120 - 126 127 - 133 134 - 140 141 - 147 148 - 154 155 - 161 162 - 168 169 - 175 176 - 182 183 - 189 190 - 196 197 - 203 204 - 210 211 - 217 218 - 255 0 - 255 0 - 127 128 - 189 190 - 193 194 - 255 18 Channel DMX Mode Function GOBOS GOBO 6 GOBO 7 GOBO 8 GOBO 9 GOBO 10 GOBO 11 GOBO 12 GOBO 13 GOBO 14 GOBO 1 SHAKE GOBO 2 SHAKE GOBO 3 SHAKE GOBO 4 SHAKE GOBO 5 SHAKE GOBO 6 SHAKE GOBO 7 SHA
Vizi Roller Beam 2R Channel 14 15 16 17 18 Value 128 - 159 160 - 191 192 - 223 224 - 255 0 - 255 0 - 255 0 - 225 226 - 235 236 - 245 246 - 255 0 - 19 20 - 29 30 - 39 40 - 59 60 - 79 80 - 84 85 - 87 88 - 90 91 - 93 94 - 96 97 - 99 100 - 119 120 - 139 140 - 159 160 - 179 180 - 199 200 - 219 220 - 239 240 - 255 18 Channel DMX Mode Function SHUTTER & STROBE PULSE EFFECT IN SEQUENCES SHUTTER OPEN RANDOM STROBE SLOW - FAST SHUTTER OPEN MASTER DIMMER 0% - 100% FINE DIMMER INTENSITY PAN/TILT MOVEMENT
Vizi Roller Beam 2R Photometric Chart Vizi Roller Beam 2R Cleaning Fixture Cleaning: Due to fog residue, smoke, and dust cleaning Intensity LUX 4 49390 21320 12110 0 4 Beam opening(m) 2 2 the internal and external optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend cleaning on a monthly basis.
Vizi Roller Beam 2R Warranty Vizi Roller Beam 2R Notes MANUFACTURER’S LIMITED WARRANTY A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
Vizi Roller Beam 2R Model: Specifications Vizi Roller Beam 2R Voltage: 100~240V, 50/60Hz Lamp: Philips® Platinum MSD 2R Discharge Power Consumption: 210W Dimensions: 17.5”(L) x 12”(W) x 9.25”(H) 439.7mm x 300mm x 233.4mm Weight: 16.75 Lbs. / 7.5 kgs.