Operating instructions
Monitor Arming
Alarm contacts are armed for a monitor using a Monitor
Arming Code which identifies the alarm Display method
(Sequence, Hold, or Dual) and the alarm Clearance method
(Instant, Auto, or Manual clear). The different Monitor
Arming Codes available in the AD2150 are shown in Table 4
and are described in the Appendix, page A-3.
To arm a monitor:
1. Turn the keyswitch to PROG position (AD2078A) or enter
the PROG mode (ADTT).
2. Call the monitor to be armed.
3. Enter the Monitor Arming Code number (refer to the
Monitor Arming Codes, Table 4).
4. Press the ARM button in the MONITOR section. The Arm
Type (see table at right) is displayed in the on-screen Status
Line for five seconds, under the camera number.
5. Turn the keyswitch to the OFF position (AD2078A) or exit
the program mode (ADTT).
For codes 13 - 15, the second (Sequence) monitor is selected
automatically (the next numeric system monitor) and armed to
the second Arm Type when the first (Hold) monitor is armed.
As an example, the Sequence, Instant Clear arming code was
selected for the monitor by entering the number 1 on the
keypad and pressing the ARM button. This results in the on-
screen display shown in Figure 3-1.
To disarm a monitor:
1. Turn the keyswitch to PROG position (AD2078A) or enter
the PROG mode (ADTT).
2. Call the monitor to be disarmed.
3. Press the OFF button in the MONITOR section.
4. Turn the keyswitch to the OFF position (AD2078A) or exit
the program mode (ADTT).
To verify the monitor arming at any time, press the keyboard
ARM button. The Arm Type is displayed for five seconds in
the on-screen Status Line. If the monitor has not been armed
or has been disarmed, the code “DIS” is displayed.
Table 4 - Monitor Arming Codes
(See Appendix pages A-3 to A-5 for code definitions.)
Code Description Arm Type
1 Single/Sequence/Instant Clear SSI
2 Single/Sequence/Auto (after 20 seconds) SSA
3 Single/Sequence/Manual (ACK key) SSM A*
4 Single/Hold/Instant Clear SHI
5 Single/Hold/Auto Clear SHA
6 Single/Hold/Manual Clear SHM A*
First Monitor Second Mon
Arm Type Arm Type
13 Dual/Hold and Sequence/
Instant Clear DHI DSI
14 Dual/Hold and Sequence/
Auto Clear DHA DSA
15 Dual/Hold and Sequence/
Manual Clear DHM A* DSM A*
16 Disarm monitor DIS
* Manual Clear/Acknowledge is always enabled.
The Manual Clear/Acknowledge feature can be enabled or
disabled for any Instant Clear and Auto Clear arming code.
This must be done after a monitor is armed with one of these
codes.
To enable/disable Manual Acknowledge for Instant or Auto:
1. Turn the keyswitch to PROG position (AD2078A) or enter
the PROG mode (ADTT).
2. Call the monitor to be armed.
3. Enter one of the following code numbers on the keypad:
17 - to enable Manual ACK/Clear
18 - to disable Manual ACK/Clear
3. Press the ARM button.
5. Turn the keyswitch to the OFF position (AD2078A) or exit
the program mode (ADTT).
When enabled, the letter “A” is displayed after the Arm Type
in the on-screen Status Line (e.g., SSI A). When disabled, the
letter “A” does not appear after the Arm Type.
Monitors can also be armed using the MONITOR menu, page
4-13.
NON-MENU PROGRAMMING
Figure 3-1 - On-Screen Monitor Arming Display
3-6
001
SSI
AMERICAN
DYNAMICS
12-15-93
10:27:53
Monitor Armed for
Sequence, Instant Clear