Operating instructions
Programming the Alarm Contacts
To select an Alarm Contact for programming:
- Move the cursor to the desired Alarm Contact Number
(ACN) line of the menu (from 1 to 128).
See page 4-3 for cursor movement and paging instructions.
CAM (Camera)
To associate a specific camera with an ACN:
1. Move the cursor to the CAM column for this ACN entry.
2. Enter the desired camera number (1 to 32).
3. Press the ACK button. The selected camera number is
displayed under the CAM heading.
DWL (Dwell Time )
To set a dwell time for the camera:
1. Move the cursor to the DWL column for this ACN entry.
2. Enter the desired dwell time (1 to 60). If a 61 is entered,
the time is set to a hold condition for the particular camera.
3. Press the ACK button. The dwell time is displayed under
the DWL heading.
If presets, auxiliaries, or connect next are not required for this
ACN, repeat the CAMERA and DWELL TIME instructions in
the previous paragraphs for each ACN to be programmed. 
PRE (Preset)
If presets are desired for the camera:
1. Position the cursor to the PRE column for this ACN entry.
2. Enter the preset number (zero to 72). Zero represents no
preset call for this entry.
3. Press the ACK button. The preset number is displayed
under the PRE heading.
AUX (Auxiliary)
If an auxiliary action is desired for an ACN entry:
1. Move the cursor to the AUX column for this ACN entry.
2. Enter one of the following auxiliary selection numbers and
press the ACK button. The auxiliary selection will appear
in the AUX column.
1 = aux 1 ON 5 = aux 1 OFF
2 = aux 2 ON 6 = aux 2 OFF
3 = aux 3 ON 7 = aux 3 OFF
4 = aux 4 ON 8 = no aux call
or
Press the ACK button to cycle through the available
auxiliaries options. Press the NEXT key to accept the
displayed selection.
CN (Connect Next)
For salvo switching on alarm:
1. Position the cursor to the desired CN column and ACN
entry.
2. Enter a number for one of the following selections and
press the ACK button. The selection is displayed in the CN
column.
1 = N, no connect next
2 = Y, connect to next tour entry
3 = S, call a System Salvo
or
Press the ACK button to cycle through the CN values. The
entry displays “N”, “Y”, or “S” each time ACK is pressed.
Press the NEXT button to save the displayed entry.
If a System Salvo (S) is selected, the CAM number for this
entry must be set to the desired Salvo number. 
If Connect Next (Y) is selected, the dwell times for the salvo
group is controlled by the first entry of the group. The dwell
time for all but the first entry in the salvo group may be left
blank. All entries in a connect next sequence should have the
CN entry set to Y except the last entry, which is set to N.
Example: 
The following sample shows the entries to associate Camera
17 with ACN 007, set a dwell time of 30 seconds, a preset of
05, AUX 1 ON and salvo connect to the next entry (08).
SET ALARM CONTACTS
ACN CAM DWL PRE AUX CN
001 01 02 00 0- N
002 02 02 00 0- N
003 03 02 00 0- N
004 04 02 00 0- N
005 05 02 00 0- N
006 06 02 00 0- N
007 17 30 05 1-ON Y
008 08 00 00 0- N
PREVIOUS MENU
Note that the dwell time for entry 08 is set to zero since its
dwell time is controlled by the first entry of the salvo group,
entry 07.
MENU PROGRAMMING - SYSTEM MENU
4-11