Specifications

34
MegaPower LT
Installer Menu
The Installer menu allows access to configuration options unavailable to users with
Supervisor status. It is used to configure system options, keyboard priorities and to run
the dome ping function.
Configuring System Options
The System Options screen allows the installer to configure the unit address and baud
rate settings. Options are available for both RS485 and RS232 networks.
ADNET RS485
The Unit ID as required for RS485 multi-matrix operation is programmable between
1-32. The default ID is 09.
The RS485 Baud Rate can be defined as 9600 or 19200. Optimum performance
can be achieved by setting the baud rate to 19200 and therefore this is the default
setting. However, if the MegaPower LT is be connected to an existing ADNet RS485
network with other compatible multiplexers, the baud rate must be set to operate at
9600 baud rate.
6.1 System Options
ADNET
Unit ID :09
Baud Rate :19200
RS232 Setting
Baud Rate :38400
Data Bit :8
Parity :NONE
Stop :1
Return to Menu
6 Installer Menu
S/W Ver 1.xx
6.1 System Options
6.2 Keyboard Priority
6.3 Dome Ping
VPSynch: DISABLED
Save to User Defaults
Restore User Defaults
Restore Factory Defaults
Return to Menu