Procedure 26 Configure Exposure Settings
Step Action
1 Select Setup on the Web User Interface banner to display the setup menus.
2 Select the Picture Settings tab from the Basic Configuration menu.
3 Select to start the video stream if it is not already active.
4 Select the Exposure Mode from the drop-down menu:
Auto
Manual
Shutter Priority
5 Select the Exposure Method from the drop-down menu:
Full Picture Weighted
Upper
Lower
Center Weighted
Spot
Left
Right
The default setting is center weighted.
6 Select the Min Exposure (sec) from the drop-down menu.
The default setting is 1/10000s.
7 Select the Max Exposure (sec) from the drop-down menu.
The default setting is 1/7.5s.
8 Select the Exposure Offset (F-stops) from the drop-down menu.
The default setting is 1/8s.
9 Select the Exposure Offset (F-Stops) from the drop-down menu.
The default setting is 0.
10 Select the Max Gain (db) from the drop-down menu.
The default setting is 45db.
11 Select Exposure (sec) from the drop down.
12 The Default is 1/30.
13 Select Manual Gain from the drop down.
14 The Default is 0db.
15 Select the Frequency radio button for either 50Hz or 60Hz.
The default setting is 60Hz.
16 Select or clear the check box for Flickerless Mode.
This feature is not selected by default.
When you select Flickerless Mode, the minimum and maximum
exposure times are locked to 1/100 and 1/50 respectively (PAL) or
1/120 and 1/60 respectively (NTSC). This applies to all cameras ref-
erenced in this guide.