Product data

VideoEdge NVR 4.1 Release Notes
23
8200-2735-07 D0
Appendix C AD Fixed IP Cameras (Illustra 400)
Supported Models
Model: Illustra 400 Fix Cameras (Box, Bullet, Mini-Dome)
Supported Firmware
Firmware: Must be V2.20 or higher
Supported Key Functions
Video Streaming Single, Dual
Video Codec H.264 and MJPEG
Audio Streaming G.711 ulaw and G.726, single stream only
Dry Contact Events Single. Camera is polled for dry contact event at 100ms interval
Query Device
Device Reboot
Required Network Ports
Port 80 is for HTTP
Port 554 is for RTSP
Default Username and Password
Username: admin
Password: 9999
Limitations
The camera will reboot when changing codec (audio or video), resolution, frame rate, key
frame interval, video quality, audio volume, enable audio / audioin and any other audio / video
properties. The reboots will take about 20 to 30 seconds.
All audio and video streams will be lost when the camera reboots. All audio and video
streams will then need to be re-established.
When the camera is rebooting, video and audio properties may not be available to get / set
new value.
Dual Video streaming:
a. Stream (profile) 1 is designated for H.264 and Stream (profile) 2 is designated for
MJPEG.
b. Due to camera internal resource contention, both streams must have the same
resolution.
c. Dual H.264 and Dual MJPEG video streams are not supported in this release.
To achieve optimal H.264 Motion Detection results, the recommended settings are:
a. Stream 1 is H.264, 30fps, D1 or D2 resolution, default quality
b. Stream 2 is MJPEG, 7 fps, CIF, default quality