4 Select a profile from the list available.
5 Select Delete.
- End -
Lens Calibration
Use the lens calibration process to recover focus and zoom after motor stalling has occurred. Motor
step stalling is rare, but it can occur during shipping or through mishandling of the camera. If the One
Touch focus at Wide or Tele is not working through the zoom range, the camera requires lens
calibration. The lens calibration tool uses infinity focus curves to align the camera lens and correct
problems focusing at Wide or Tele.
Lens calibration is automatic and you can run it from the Lens Calibration tab.
Procedure 61 Run a Lens Calibration
Step Action
1 Select Setup on the Web Interface Banner to display the setup menus.
2 Select Picture Settings from the Video menu.
3 Select the Lens Calibration tab.
4 Select Start Calibration and wait for the camera lens initialization to complete.
5 To confirm the success of the lens calibration, select the Picture Basic tab from the
Picture Settings menu and verify that the image is in focus through the zoom range.
Use the OneTouch button to automatically focus the area.
- End -
Date / Time / OSD
Change the Camera Name, Date and Time and enable On-Screen Display (OSD).
Date Time
You can change the camera name and set the date and time.
Procedure 62 Change the Camera Name
Step Action
1 Select Setup on the Web User Interface banner.
2 Select Date / Time / OSD from the Video menu.
3 Enter the name of the camera in the Camera Friendly Name text box.
- End -