Installation Guide

Illustra Pro Gen 4 2MP, 4MP and 8MP Domes Installation and Configuration Guide
8200-2007-08 A0 73
Send an external alarm through email that includes alarm detail, where to retrieve the
AVI video file and one JPEG picture of the event if recording MJPEG to local storage. If
MJPEG is not being recorded on local storage, then no JPEG picture is sent.
Send an audio file through the unit. If a speaker has been connected to the audio output
on the unit the file can be played as the alarm is triggered.
Send an AVI video file to a pre-configured external FTP server. The video file contains
pre and post alarm video buffer and audio if enabled and supported, as outlined above.
Note:
1. An active internal alarm only resets when the input state changes to “normal. A
manual reset is not available.
2. A micro SD Card must be inserted to send an SMTP email, video files, audio and
images from triggered alarms.
Procedure 81 Configure an Alarm
Step Action
1 Select Alarm I/O from the Event and Actions menu.
2 Enter the alarm name in the Name text box.
3 Select the Enabled check box to enable the alarm.
OR
Clear the Enabled check box to disable to alarm.
4 Select when the alarm is required to be activated from the Normal drop-down menu. i.e.
when the dry contact is open or closed.
5 Select the required configured fault action from the Action drop down menu.
- End -
Procedure 82 Enable/Disable an Alarm
Step Action
1 Select Setup on the Web User Interface banner to display the setup menus.
2 Select Alarm I/O from the Event and Actions menu.
3 Select the Enabled check box to enable the corresponding alarm.
OR
Clear the Enabled check box to disable the corresponding alarm.
- End -
Enable or Disable Alarm Output
Alarm Output allows the alarm to activate a digital output as an action. For example, this digital
output could be linked to an electrical device, i.e. a security light or siren.