Specifications

SPEEDDOME ULTRA VII CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0184-01, REV. A1)
13 of 41
Connecting to the
Standard Mounting Base
This procedure explains how to connect the
housing and eyeball assembly to a standard base.
WARNING: Ensure that ac power and
electrical signals are off during wire
connections!
1. Set the dome address (Figure 10).
Recessed at the top of housing and eyeball
assembly are three rotary address switches.
Address range is from 001 to 255, except for
Manchester, which is 01 to 64.
Set switches from most significant bit (MSB)
to least significant bit (LSB). For example:
For address 166, set SW3 to 1, SW2 to 6,
and SW1 to 6.
If using the following protocols, special address
settings are required:
Pelco Coaxitron Communications Protocol:
To set the camera dome for the Pelco Coaxitron
communications protocol, set dome address
switches to 893.
Panasonic UTC Communications Protocol:
To set the camera dome for the Panasonic UTC
communications protocol, set dome address
switches to 890.
Pelco P Communications Protocol: To set the
camera dome for the Pelco P communications
protocol, do one of the following:
· For 2400 baud–Set the x100 dome address
switch to 6. The x10 and x1 switches can be
set to any camera address.
· For 4800 baud–Dome address switches are
not used. Set the x100 to “0”. The x10 and
x1 switches can be set to any camera
address.
· For 9600 baud–Set the x100 dome address
switch to 7. The x10 and x1 switches can be
set to any camera address.
Figure 10. Setting address switches
090909
MSB
LSB
SW3
SW1SW2
2. Attach the safety lanyard to the cap on the
housing and eyeball assembly (Figure 11). Use
the M3 x 6 screw supplied with the lanyard.
Figure 11. Attaching safety lanyard
Only use this
location to secure
lanyard.
!