Specifications

SPEEDDOME ULTRA VII CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0184-01, REV. A1)
14 of 41
3. WITH POWER OFF, connect the video cable
(Figure 12).
a. Connect BNC of video micro coax cable
6003-0170-01 to BNC of video cable.
b. Feed cable through access hole in base.
c. Press the micro coax connector into the
mating receptacle in the top of the housing
and eyeball assembly. A firm snap indicates
a tight connection.
4. For the dome at the end of a daisy chain, set
termination jumper JW1 on the dome CPU
board (Figure 12) to “terminated”.
Position of dome in
communications line… Setting Pins
Between other devices Unterminated 1-2*
End of communications line Terminated 2-3
* Pins 1-2 are closest to 9-pin connector.
Note: You may need a small slotted screwdriver
to gently pry the jumper loose. Be careful not to
damage the underlying PC board.
Figure 12. Video cable connection and
termination jumper location
5. Connect the 9-pin plug (data and power) to the
9-pin receptacle (Figure 13). If using a Pelco
Coaxitron or Panasonic UTC protocol, no data
wires are connected, just power.
CAUTION: DO NOT connect the 9-pin plug
unless you have performed step 3 first!
a. Feed cables through the access hole in the
base.
b. Connect data and power wires to the 9-pin
plug (refer to charts below).
c. Insert the plug into the mating receptacle in
the top of housing and eyeball assembly.
Manchester data and power connections.
Order data cable 88760 (plenum) or 8760
(non-plenum) from Belden by calling
1-800-235-3361.
Pin Color Designation
1 White Manchester (–)
2 Black Manchester (+)
3 Black 24Vac
4 Red Ground
5 White 24vac
6-9 — Not used.
RS422/Pelco P data and power connections
Pin Color Designation
1-2 — Not used.
3 Black 24Vac
4 Red Ground
5 White 24Vac
6 Orange RS422 Data In High (+)
7 Green RS422 Data In Low (–)
8 Yellow RS422 Data Out High (+)
9 Brown RS422 Data Out Low (–)
SensorNet data and power connections
Pin Color Designation
1 Orange SensorNet (unshielded)
2 Yellow SensorNet (unshielded)
3 Black 24Vac
4 Red Ground
5 White 24Vac
6-9 — Not used.
Termination
Jum
p
er JW1
Micro
Coax
Cable