10. Set the dome address (Figure 17).
Recessed at top of the housing and eyeball
assembly are three rotary address switches.
The address range is from 001 to 255, except
for Manchester, which is 01 to 64.
Set switches from most significant bit (MSB)
to least significant bit (LSB). For example:
For address 166, set SW3 to 1, SW2 to 6,
and SW1 to 6.
If using the following protocols, special address
settings are required:
Pelco Coaxitron Communications Protocol:
To set the camera dome for the Pelco Coaxitron
communications protocol, set dome address
switches to 893.
Panasonic UTC Communications Protocol:
To set the camera dome for the Panasonic UTC
communications protocol, set dome address
switches to 890.
Pelco P Communications Protocol: To set the
camera dome for the Pelco P communications
protocol, do one of the following:
· For 2400 baud–Set the x100 dome address
switch to 6. The x10 and x1 switches can be
set to any camera address.
· For 4800 baud–Dome address switches are
not used. Set the x100 to “0”. The x10 and
x1 switches can be set to any camera
address.
· For 9600 baud–Set the x100 dome address
switch to 7. The x10 and x1 switches can be
set to any camera address.
Figure 17. Setting address switches
090909
MSB
LSB
SW3