SPEEDDOME ULTRA VII CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0184-01, REV. A1)
41 of 41
RS422: Set the domes address switches to 900
test mode, then apply power. After approximately
20 seconds, the three LEDs do the following:
Red Green Yellow
Control
3
Possible Cause
Mostly
Off,
Blinking
On
Mostly
Off,
Blinking
On
Rapidly
Blinking
Yes RX+ (pin 6) and RX–
(pin 7) correctly
wired.
Mostly
Off,
Blinking
On
Mostly
Off,
Blinking
On
Rapidly
Blinking
No Wire to RX+ (pin 6)
not connected.
Mostly
On,
Blinking
Off
Mostly
On,
Blinking
Off
Rapidly
Blinking
No Wires to RX+ (pin 6)
and RX– (pin 7)
reversed.
Off On Alternat
ing Off
and On
Every
60 Sec.
No Wire to RX– (pin 7)
not connected.
Wires to RX+ or RX–
not connected or
shorted together.
Wires to RX+ and/or
RX– shorted to ac
ground.
3
When not in address 900 test mode.
When done testing, reset the address switches
back to the camera address.
SensorNet: After approximately 20 seconds, the
three LEDs do the following:
Red Green Yellow Control Possible Cause
Blinking
Steady,
then
Rapidly
Blinking
Steady,
then
Off
4
Yes
Pins 1 and 2
correctly wired.
4
When data for
this dome is
received.
Thereafter, the
yellow LED will
flicker when
data is sent to
this dome.
Blinking
Steady,
then
Rapidly
Blinking
Steady,
then
Off
5
No
Wires to pin 1
and/or pin 2
shorted to ac
ground.
5
When data for
this dome is
received.
Blinking
Steady,
then
Rapidly
Blinking
Steady No
Wire to pin 2 not
connected.
Blinking
Steady,
then
Blinking
Steady No
Wires to pins 1
and 2 shorted
together.
Wire to pin 1 not
connected or
both wires to
pins 1 and 2 not
connected.