Instruction Manual

American Electric Lighting a division of Acuity Lighting Group, Inc. Granville, OH
DRAWING NO. A72083 REV -- (BACK)
©2008 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-72083
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
POST TOP LUMINAIRE 247 SERIES & TCL cont. cont.
MOUNTING:MOUNTING:
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH ANNOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
SUPPLY LEADS THROUGH THE BASE OF THE UNIT. SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
NOTE: IF UNIT IS PRE-WIRED, FEED THE SUPPLIED NOTE: IF UNIT IS PRE-WIRED, FEED THE SUPPLIED
PRE-WIRE THROUGH THE POST TOP AND DOWN THE PRE-WIRE THROUGH THE POST TOP AND DOWN THE
POLE.POLE.
2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW
(OR TRIGGER LATCH IF EQUIPPED) ARE TO THE (OR TRIGGER LATCH IF EQUIPPED) ARE TO THE
STREET SIDE. STREET SIDE.
3. TIGHTEN THE THREE MOUNTING SET SCREWS.3. TIGHTEN THE THREE MOUNTING SET SCREWS.
WIRING:WIRING:
NNOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT ISOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
SUPPLIED WITH PRE-WIRE.SUPPLIED WITH PRE-WIRE.
1. OPEN THE UNIT AND REMOVE THE STREET SIDE LENS.1. OPEN THE UNIT AND REMOVE THE STREET SIDE LENS.
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
INSIDE OF THE HOOD. INSIDE OF THE HOOD.
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK. THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
TERMINAL BLOCK, AND TIGHTENING THE SCREW TERMINAL BLOCK, AND TIGHTENING THE SCREW
SECURELY. SECURELY.
5. REINSTALL THE STREET SIDE LENS.5. REINSTALL THE STREET SIDE LENS.
6. CLOSE THE UNIT.6. CLOSE THE UNIT.
LAMP INSTALLATION:LAMP INSTALLATION:
11. OPEN THE UNIT. . OPEN THE UNIT.
2. SECURELY INSERT LAMP INTO LAMP SOCKET.2. SECURELY INSERT LAMP INTO LAMP SOCKET.
3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY
DEPRESS AND LOAD THE CENTER CONTACT OF THE DEPRESS AND LOAD THE CENTER CONTACT OF THE
SOCKET. SOCKET.
NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.
4. CLOSE THE UNIT.4. CLOSE THE UNIT.
5. ENERGIZE AND VERIFY OPERATION.5. ENERGIZE AND VERIFY OPERATION.
PHOTOCONTROL CONT:PHOTOCONTROL CONT:
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND
LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID
AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF. AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.
HOWEVER, IT MAY BE REMOVED BY HAND. HOWEVER, IT MAY BE REMOVED BY HAND.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A 3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A
VERY AUDIBLE SNAP. VERY AUDIBLE SNAP.
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY 4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND
TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS
FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL
RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS
THE CUPOLA DOES. THE CUPOLA DOES.
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA ISNOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
STOPS AND REFUSES TO TURN.STOPS AND REFUSES TO TURN.
LL ADDER REST INSTALLATION:ADDER REST INSTALLATION:
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.
HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT
AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KITAND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT
(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)
NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDEDNOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED
FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THEFOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE
POST TOP.POST TOP.
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)
INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND
RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT
SET SCREWS. SET SCREWS.
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE
LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER
REST LINED UP WITH THE HOLE SO THAT THERE IS NO REST LINED UP WITH THE HOLE SO THAT THERE IS NO
DAMAGE TO THE PIN. DAMAGE TO THE PIN.
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVENOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
AND NUT.AND NUT.
CAUTION
DO NOT TIGHTEN SET SCREWS
BEYOND 15 ft-lb. TORQUE.
!
PHOTOCONTROL:PHOTOCONTROL:
NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-
CONTROL INSTALLATION OR ADJUSTMENT. CONTROL INSTALLATION OR ADJUSTMENT.
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A - IF NO PHOTOCONTROL OPTION WAS SELECTED, A
CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED
TO BE INSTALLED. SEE STEP 1 BELOW. TO BE INSTALLED. SEE STEP 1 BELOW.
- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL
COME WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4 COME WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4
BELOW. BELOW.
- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH - IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH
A SHORTING CAP AND THE STEPS BELOW ARE NOT A SHORTING CAP AND THE STEPS BELOW ARE NOT
NECESSARY. NECESSARY.
CAUTION
THE LADDER REST IS FOR COSMETIC
PURPOSES ONLY. IT IS NOT
INTENDED FOR USE AS AN ACTUAL
REST FOR A LADDER.
!
FIGURE 3FIGURE 3
LADDER REST INSTALLATIONLADDER REST INSTALLATION
PINPIN
GENTLY KNOCK HEREGENTLY KNOCK HERE
FOR INSTALLATION.FOR INSTALLATION.
IF LAMP IS MARKED IF LAMP IS MARKED
IT CONTAINS MERCURY.IT CONTAINS MERCURY.
FOLLOW DISPOSAL LAWS.FOLLOW DISPOSAL LAWS.
SEE WWW.LAMPRECYCLE.ORGSEE WWW.LAMPRECYCLE.ORG
Hg