User guide

Version 4.0 36
certified professional to install a flue gas pellet venting system. Do not deviate from the pellet
flue manufacturer’s installation instructions. Contact Country Flame or a local authorized dealer
to resolve any questions or installation procedures. TABLE 4 shows the required components
needed for a typical pellet flue pipe mobile home installation. Contact Dura-Vent or other
authorized flue pipe dealers for the latest specifications and costs for mobile home pellet stove
flue pipe parts or for a mobile home flue pipe kit from an authorized chimney dealer.
TABLE 4: MOBILE HOME (minimum) CHIMNEY SYSTEM REQUIRED PARTS
PART NUMBER DESCRIPTION QTY
3180 VERTICAL CHIMNEY CAP 1
3149 0/12 – 6/12 ADJUSTABLE ROOF FLASHING 1
3151 (ALTERNATE) ROOF FLASHING, Flat (versus 3149) 1
3142 CEILING SUPPORT BOX, Fire Stop Spacer 1
3141 (ALTERNATE) CATHEDRAL CEILING SUPPORT BOX, (versus 3142) 1
3160B 5 FOOT CHIMNEY SECTION 2
3179 STOVE PIPE ADAPTER (if needed) 1
CERAFORM 126 WALL PROTECTION ( IF REQUIRED) 1
3145B 45
0
ELBOW (if needed) 1
3159 STORM COLLAR 1
NOTE: The information provided in TABLE 4 and detailed in FIGURE 15 are for informational
purposes. These corn flue pipe system parts may or may not be needed depending on site specific
conditions found in the specific mobile home application. Consult a certified professional and insure that
any installation meets all federal, state, and local building codes. Failure to follow the flue pipe
manufacturer’s installation instructions will void Country Flame’s product warranty and can have an
adverse impact on the homeowner’s insurance policy. Contact Country Flame or one of its local
authorized dealers to resolve any questions about installation or parts usage.