User Manual

38
PROBLEM CAUSES SOLUTIONS
? Fire goes out or stove shuts down
automatically.
Hopper is empty.
Fuel is not feeding.
High limit temperature switch has
tripped.
Vacuum pressure switch has
tripped.
Poor quality or wet fuel.
Combustion air too high.
Fuel feed rate is too low.
9 Refill hopper.
9 See “Pellets will not feed” below.
9 Allow stove to cool for 1 hour and
relight after re-setting the high
temperature thermodisk. If this
problem persists, particularly at
lower burn rates, then the high limit
snap switch should be replaced by
your authorized Magnum reseller.
9 Correct cause of pressure switch
tripping. Have an authorized tech
service unit. Install outside air.
9 Replace fuel with proper fuel.
9 Adjust the damper to reduce
combustion airflow.
9 Have your Magnum reseller adjust
the fuel control.
? Fuel will not feed.
Hopper is empty.
Auger, circuit board, high limit
switch tripped
Foreign object caught in auger
Fuel is dirty or wet
Auger, circuit board, pressure
switch or relay.
9 Check contents of the hopper. Add
fuel if necessary.
9 Check all operation, fuses, re-set
manual high limit thermodisk
9 Clean out auger system
9 Have your Magnum reseller
diagnose the problem and replace
the parts.
? Stove runs for 15 minutes and then
shuts down.
Exhaust gas is not up to
temperature.
Low limit snap switch not operating
correctly; may be defective.
Wires to either the low limit snap
switch (mounted on the side of the
firebox) are loose or disconnected.
9 Relight the stove.
9 Have your Magnum reseller replace
the low limit switch.
9 Contact your Magnum reseller for
service.
? Blower will not shut off after the fuel
has been switched off and the stove has
cooled down.
Low limit snap switch has failed in
the closed position.
Unit has not cooled down yet.
9 Have your Magnum reseller replace
the low limit snap switch.
9 It can take up to 1 hour for the unit
to cool down enough for the blower
to shut off. If it takes longer than 2
hours for the blower to shut off or if
it fails to shut off contact your local
Magnum service technician.