PROBLEM CAUSES SOLUTIONS
? Blower will not operate.
No power to stove.
No power to control board.
Blower is defective
9 Check to see that the stove is
plugged into the wall outlet.
9 Check to see if your circuit breaker
has “tripped”.
9 Check wire connection between the
high limit snap switch and the
terminal block.
9 Replace defective Blower
? Soot or fly ash in the house.
Cleaning the window, particularly
when the stove is operating.
Leakage on the joints between the
combustion fan, exhaust pipe and
“PL” vent. This will be evidenced
by dust on the impeller of the
convection fan and in the heat
exchanger tubes.
Negative pressure in the home
drawing smoke and fly ash into the
home
9 Clean the glass when the unit is not
running
9 Seal any leaks in the exhaust
system with RTV high temperature
silicone sealer.
9 Have a qualified technician check
the home for negative pressure and
install proper make up air if needed.
? Buildup of soot on glass, venting and
heat exchangers
Dirty fuel
Negative pressure in home
Air wash plugged or out of
adjustment
9 Make sure you have clean fuel
9 Pull manual draft control out
slightly to make sure that there is
app. ½ inch of fuel in firepot
9 Install outside air to unit and make
sure that the home has adequate
make-up air. (suggested 6” make-
up air into basement)
9 Clean air-wash system located on
front of firepot holder and face
plate.
CAUTION: WHEN PERFORMING ANY INTERNAL ELECTRICAL MAINTENANCE
MOVING PARTS INSIDE OF THE CABINET MAY CAUSE INJURY. DO NOT OPERATE UNIT WITH PANELS
REMOVED OR OPEN.
HOT PARTS. DO NOT OPERATE THE UNIT WITH PANEL OPEN.
RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IN THE EVENT OF COMPONENT FAILURE, REPLACE WITH ORIGINAL FACTORY EQUIPMENT.
Replacement Parts List
Part # Description Part # Description Part # Description
RP2035 Comb./Room fan RP2020 2 rpm 12V auger motor RP2091 Auger assembly
RP2091 Auger Bushing kit RPT2800 DCX-5 circuit board RT050 Power Supply
MF3538 L-250 Hi-limit switch MF3537 F-110 Fan switch RT080 Pressure switch .1
RP2096 Neoprene ¼”ID hose RT100 Standard black door RT110 Gold Plated door
RT120 Door handle assembly RT130 Door glass w/gasket R0082 Glass Gasket kit
R0080 Door Gasket, ½” rope R0080 Cover hinge gasket RT180 Firepot
RT190 Ash receptacle buckets RT200 Black air deflector RT230 Gold air deflector
RT210 Black Cooktops (ea) RT220 Gold Cooktops (ea) MF3536 Door Safety switch