Manual

Installation instructions for E4 Series and LD4 Series
CAUTION: Always make sure power to the fixture is disconnected before beginning removal of
existing lamp and/or trim, or before beginning retrofit installation. Failure to do so can cause
electric shock, which can result in injury or death.
RETROFIT INSTALLATION
1. Confirm the LED trim is compatible with the recessed housing as outlined on reverse.
2. Remove existing lamp from existing recessed housing.
3. Remove existing trim from existing recessed housing.
4. Detach GU24 or E26 socket adaptor from LED fixture by grasping plastic connectors
firmly and pulling apart. Do not grasp wires to pull connectors apart. See Figure 2.
5. Screw E26 socket adaptor into existing E26 socket at the back of the housing; or push
and twist GU24 socket adaptor into existing GU24 socket at back of housing. See Figure 3.
6. Insert male connector pins into female connector and press firmly together until fully
seated. See Figure 4.
7. Anchor fixture to recessed can, aligning steel spring clips with interior wall of can, and
push fixture gently to ceiling until seated. See Figure 5.
Figure 2
Figure 4
Recessed
housing
Ceiling
Ceiling
Figure 3
Insert male connector
pins into female
connector and press
firmly together until
fully seated
Steel spring
clips
pg 2 of 2
Denver, CO 80231 www.americanlighting.com
© 2012 American Lighting, Inc RV1216
NEW CONSTRUCTION INSTALLATION
Follow steps 1, then 4-7 above.
4” LED Recessed Downlight
Figure 5
E4 Type Installed
LD4 Type Installed
Ceiling
Recessed
housing