Installation Sheet

Page 1 of 4 11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
TRULUX
®
RGB + TUNABLE WHITE (IP54)24V
INSTALLATION INSTRUCTIONS
SPTL-RGBTW Series
©2021 American Lighting, Inc. REV2112 www.AmericanLighting.com
SAFETY INFORMATION
Read all installation instructions before beginning; if not qualified, do not
attempt installation. Contact a qualified electrician.
To reduce the risk of fire, electric shock, or injury to persons, pay close
attention to this manual and stay within its guidelines when using this
product. Save these instructions for future use.
Do not cover this product with paper surface coverings, fabrics,
streamers, or other similar combustible materials.
Do not operate Trulux on the reel, nor while it is coiled.
This IP54 rated tape light is suitable for indoor use in dry and damp
locations, but not for direct contact with water or moisture Do not
submerge flexible light in liquids, or use the product in the vicinity of
standing water or other liquids, or where water can accumulate.
Do not route the cord or tape light through walls, ceilings, doors,
windows, or any similar part of the building structure.
Secure tape light using only the adhesive provided with the tape
and/or factory recommended mounting clips, mounting track, and
aluminum channel (sold separately).
Do not secure this product or its cord with staples, nails, or like means
that may damage the outer jacket or cord insulation.
Do not use if there is any damage to the tape light, diodes or power cord
insulation; inspect periodically.
Do not install on gates or doors, or where subject to continuous flexing.
Do not install in airtight tanks or enclosures of any kinds.
Size your 24V DC driver appropriately for your run distance. Be sure not
to load a driver to 100% as this will reduce its eciency; a 90% maximum
load is recommended. See LED-DR DRIVERS on page 2 and use driver
chart as directed.
These products may represent a possible shock or fire
hazard if improperly installed or attached in any way.
Products should be installed in accordance with these
instructions, current electrical codes, and/or the current
National Electric Code (NEC).
Use only with 24V DC drivers with a wattage capacity
that can handle the total load. Factory warranty will be
void if used with a non-recommended power supply,
transformer, or driver.
To reduce the risk of fire, electric shock or injury to
persons, make sure that the electrical power to the
system is disconnected at the source prior to installation
or any servicing.
Never fold Trulux® or bend past the minimum bending
radius of 1” whether lighted or unlighted.
WARNING
WARNING
WARNING
WARNING
PRODUCT INFORMATION
IP54 reels include (3) TL-6PWR power connector kits with each reel.
Mount tape light using the 3M® VHB adhesive. Once the VHB protective backing is removed, the tape should be placed on the prepared mounting surface and not
be repositioned, removed, or re-used. For best results, let adhesive cure 24 hours prior to first use.
Trulux® RGB+TW controller (DMX-RGBTW-1Z) and a 5 channel receiver (REC-DMX-RJ45A-5CH) are required for color control of RGB+TW Trulux®. See individual
controller instructions for more details.
LAYOUT CONSIDERATIONS:
Pay close attention to the following tape light maximum run lengths. Use only the 24V DC power supply provided.
Tape Light Series Wattage Reel Length Cuttability Tape Light Kit Maximum Run
SPTL-RGBTW Series 7W/ft 13.1 feet (4m) Every 3.56” 13.1 feet (4m)
When using standard snap
connectors, it is recommended
to scrape o the coating from
each conductor to ensure a
proper connection. When using
heavy duty snap connectors, this
is only necessary for IP65 and
IP68 types.

Summary of content (4 pages)