Product Specs

2
R70210 REV E
* The American Range Company continually improves its products and reserves the right to change materials, specications and dimensions without notice.
This unit is manufactured for residential use only.
This appliance should not be installed with an air curtain or other type of ventilation system that blows air downward toward the range. Such type of ventilation system may cause ignition
and combustion problems with the gas cooking appliance resulting in personal injury or unintended operation.
| Page
13592 Desmond St. Pacoima, CA 91331 USA • www.americanrange.com
T • 888.753.9898
Drop In Cooktop 04112016
Drop-In Cooktops| Specifications
Vitesse Series with Sealed Burners
Model Width Depth Height Burners Total BTU KW Shipping Weight Lbs (Kg)
ARDCT-305 30” 21” 3-1/2” 5 73,000 (21) 50 (23)
ARDCT-365 36” 21” 3-1/2” 5 78,000 (23) 60 (27)
ARDCT-366 36” 21” 3-1/2” 6 91,000 (26) 70 (32)
Must ship from factory with proper gas type. N=Natural gas L= LP Gas Must provide N or L after model number for type of gas needed. Example: ARDCT-305-L Must specify elevation if over 2000 ft. when ordering.
TECHNICAL SPECIFICATIONS
LEGEND
MODEL
A B
ARDCT-305 29” 30”
ARDCT-365 35” 36”
ARDCT-366 35” 36”
FEATURES
Sealed burners
Up to 21,000 BTU
Bead-blasted sump area
Brass valves
Very low simmer setting, as low as 500 BTUs.
Brass burner heads.
Porcelain burner caps.
Brass valves for long lasting accurate ame settings
Continuous commercial-grade cast iron grates allows for easy transfer for pots
and pans across the cooking surface.
Die-cast black satin knobs with chrome trim.
ACCESSORY
Wok Ring Adapter
ARDCT365 ARDCT366ARDCT305
21,000 BTU (lg) 18,000 BTU (md) 13,000 BTU (sm)
BURNER CONFIGURATION
RECOMMENDED LOCATION OF GAS AND ELECTRICAL SUPPLY ISLAND OR PENINSULA INSTALLATIONS 10” MINIMUM CLEARANCE FROM BACK OF RANGE TO COMBUSTIBLE SURFACE. ISLAND TRIM 0 IN. CLEARANCE
TO NON-COMUSTIBLE SURFACE. NO SIDE WALL ABOVE COOKING SURFACE.
THIS APPLIANCE SHOULD NOT BE INSTALLED WITH AN AIR CURTAIN OR OTHER TYPE OF VENTILATION SYSTEM THAT BLOWS AIR DOWNWARD TOWARD THE UNIT. SUCH TYPE OF VENTILATION SYSTEM MAY CAUSE
IGNITION AND COMBUSTION PROBLEMS WITH THE GAS COOKING APPLIANCE RESULTING IN PERSONAL INJURY OR UNINTENTED OPERATION.
OO
G E
12"
30"
B
13"
36"
18"
1
5/8
" MIN.
COOKTOP
DEPTH
1/4" to combusitble material
below cooktop chassis
19
1/8
"
3"
A
2" MIN.
21"
IN. MIN COMBUSTIBLE TO
COUNTER TOP (TYP.)
COUNTERTOP
FLOOR
30" MIN FROM
COUNTER TOP
TO COMBUSTIBLE
MATERIAL
MIN COMBUSTIBLE
MATERIAL (TYP.)
CABINET DEPTH
FRONT VIEW SIDE VIEW
TOP VIEW
3
1/2
"
OVERALL
CUTOUT
OVERALL