User Manual

RANGETOP
Use & Care Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
6
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
The location selected for the rangetop must meet the following criteria. If any of these criteria are not met, select another location.
CABINET PREPARATION
This rangetop is a free standing unit.
The rangetop can be placed in various positions with respect to the cabinet
front,withthefronteitherushorprojecting,dependingonthecountertopwidth.
The rangetop is zero-clearance safe against non-combustible surfaces.
The maximum depth of overhead cabinets installed on either side of the hood is 13".
Anyopeningsinthewallbehindtherangetopandintheoorundertherangetopmustbesealed.
When there is less than 12" clearance between combustible material and
the back edge of the rangetop above the cooking surface, a backguard must be installed.
When clearance to combustible material is over 12" no backguard is necessary.
Back guards must be ordered separately. To order, measure the space that the
back guard must have and order accordingly.
ELECTRICAL CONNECTION
0 The rangetop must be electrically grounded in compliance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA70.
0 This rangetop requires a 120 volt supply to operate the ignition system. The supply cord provided on the rangetop is
equipped with a three-prong (grounding) plug for protection against electrical shock.
0 The electrical service in the building must be equipped with a properly grounded three-prong receptacle.
0 Do not cut or remove grounding prong from this plug.
POWER REQUIREMENTS FOR THIS RANGETOP
0 120 VAC, 60 Hz, single phase, 15 AMP Max
GAS CONNECTION
Be certain the appliance being installed is correct for the gas service being provided. Refer to the appliance data plate for the gas
supply requirements.
A manual gas shut-off valve must be remotely installed and easily accessible in the adjacent cabinet. The regulator inlet is for a 3/4
inch gas line. The appliance ships with a 1/2 inch to 3/4 inch adapter connected to the regulator.
0 Useatleasta1/2"commercialexhosetoconnectrangetoptothegassupply(serviceline).
0 A manual gas shut-off valve must be installed, in easy access in front of the gas supply (service line) and ahead of the rangetop
for safety and ease of maintenance.
0 All valves must be in the OFF position before connecting to the gas supply line.
INSTALLATION INSTRUCTIONS