Installation Guide

5 5a
6
7
8
9
730235-100 Rev. H
AMERICAN STANDARD ONE-YEAR LIMITED WARRANTY
If inspection of this American Standard plumbing product, within one year after its initial installation, confirms that it is defective in
materials or workmanship, American Standard will repair or, at its option, exchange the product for a similar model.
This limited warranty does not apply to local building code compliance; since local building codes vary considerably, the purchaser
of this product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty
maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American Standard's instructions; or if it
has been modified in a manner inconsistent with the product as shipped by American Standard.
American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal
or installation, nor shall American Standard be responsible for any other incidental or consequential damages attributable to a
product defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some
states or provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to
province, in which case this warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the
product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the following
address:
In the United States:
American Standard, Inc.
One Centennial Ave.
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
Toll Free: (800) 442-1902
In Canada:
American Standard, Inc.
2480 Stanfield Rd.,
Mississauga, Ontario
Canada L4Y 1S2
Toll Free: (800) 387-0369
In Mexico:
Customer Service Manager
American Standard, Inc.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Saniwares
B
C
Install lavatory anchor
screws leaving 1-7/8"
threaded end exposed
as illustrated.
1-7/8"
ANCHOR SCREW
INSTALLATION
Use lag bolts to secure
lavatory as illustrated.
LAG BOLT
INSTALLATION
Anchor
Screw
Washer
Lavatory
Nut
Lag
Bolt
Washer
Lavatory
Lavatory
Steel
Hanger
IMPORTANT: Final assembly of nut and washer or lag bolt method
shown for reference only. (See steps 8 and 9).
Shut-Off
Valves
Rear
View
Pedestal
Screws
A
Return the fitted lavatory to the installed
position. Connect trap to drain assembly
hand tight to check alignment. It may be
necessary to cut off part of the tailpiece
(area "B") or
part of the
horizontal leg
of the trap
(area "C").
Following manufacturer's instructions,
install faucet and drain assembly (not
included). Be certain to apply a bead of
sealing putty
on the
underside of
the drain (area
"A") in order to
ensure a
watertight seal
between the
lavatory and
drain. Remove
excess putty
after installing
drain on
lavatory.
Secure lavatory to wall as
shown in 5 or 5a. Install
washers and hand tighten nuts
or lag bolts. Level and square
the unit. Connect hot and cold
supply lines to the shut-off
valves. Tighten trap joints for
watertight assembly.
Install pedestal screws.
Securely tighten lavatory
anchor nuts or lag bolts.
Note: Space constraints may
dictate method of fastening
pedestal to floor.
www.AmericanStandard-US.com
www.AmericanStandard.ca
www.AmericanStandard.com.mx