CARE INSTRUCTIONS:
Turn valve to OFF position.
Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
Pull off HANDLE (3) and CAP (4).
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6).
Inspect CARTRIDGE (6) and O-RINGS (7) for debris and
clean if necessary.
Clean MANIFOLD (8) and rinse clean.
Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8).
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
1
2
4
5
6
2.5mm HEX KEY
REMOVE
INSTALL
3
7
10
11
SERVICE
To remove or replace cartidge:
If spout drips, operate handle several times from OFF to ON and
HOT to COLD position. Do not force - handle turns only 90˚.
Turn off hot and cold water
supplies before beginning.
CAUTION
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
3
1
OFF
ON
COLD
HOT
4
10
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill Bidet with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Bidet. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
5
“P” TRAP
WASTE
OUTLET
2
2