Use and Care Guide

H134
© 2012 AS America Inc.
PRINCETON
RECESS BATH
AMERICAST
®
BRAND ENGINEERED MATERIAL
Revised 8/12
GENERAL SPECIFICATIONS FOR 2390/2391 BATHING POOL
60 x 30 x 14 In. (1524 x 762 x 356mm)
110 Lbs. (50 Kg.)
460 Lbs. (209 Kg.)
42 Gal. (159 L)
42 x 19 In. (1067 x 483mm)
56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
37 Lbs./Sq.Ft. (175 Kgs./Sq.m)
6.2
18.1
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
GENERAL SPECIFICATIONS FOR 2392/2393 BATHING POOL
60 x 30 x 17-1/2 In. (1524 x 762 x 445mm)
119 Lbs. (54 Kg.)
469 Lbs. (213 Kg.)
42 Gal. (159 L)
42 x 19 In. (1067 x 483mm)
56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
38 Lbs./Sq.Ft. (182 Kgs./Sq.m)
7.4
21.2
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
NOTES:
LEFT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS.
(2391.202.ICH).
DRAIN AND OVERFLOW ESCUTCHEON INCLUDED WITH BATH.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH
FOR DRAIN INSTALLATION.
BATH FAUCET NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH FITTING.
CONCEALED PIPING NOT FURNISHED.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range
of tolerances established by ANSI Standard A112.19.4 These measurements
are subject to change or cancellation. No responsibility is assumed for use of
superseded or voided leaet.
WOOD STUDS STEEL STUDS
Below is shown typical cross sections of the tub
rim showing typical wall constructions.
51 x 102mm (2 x 4) WOOD
STRINGER FULL LENGTH
STUD
SHIM
DRY WALL
TILE
CAULKING/
SEALANT
TUB
DRYWALL SCREW
DRYWALL
SCREW
STEEL STUD
SHIM
DRY WALL
WASHER
TILE
DRYWALL
SCREW
CAULKING/
SEALANT
WASHER
TUB
DRYWALL
SCREW
BARRIER FREE
© 2012 AS America Inc.
*
PLUMBER NOTE: PROVIDE FULL
LENGTH SUPPORT STRINGER
AT THIS POINT
BELOW FLOOR ROUGH
2390.202 2391.202
ABOVE FLOOR ROUGH
2392.202 2393.202
LEFT HAND TUB ILLUSTRATED
RIGHT HAND TUB IS REVERSED
*
*
2-1/2"
(64mm)
DIA.
2-1/2"
(64mm)
DIA.
15/16"
(23mm)
2-1/2"
(64mm)
2-3/8"
(60mm)
15/16"
(23mm)
2-1/2"
(64mm)
14"
(356mm)
3/4"
(19mm)
3/4"
(19mm)
17-1/2"
(445mm)
30"
(765mm)
14-1/4"
(362mm)
1-7/8"
(48mm)
3-1/2"
(89mm)
17-1/8"
(435mm)
13-3/4"
(349mm)
9" X 12" (229 x 305mm)
HOLE IN SUB FLOOR
FOR BELOW FLOOR ROUGH
FINISHED
WALL
LAYBACK
ANGLE
120˚
FINISHED
WALL
FULL LENGTH
SUPPORT STRINGER
STD. 1-1/2
DRAIN OUTLET
PROVIDE
FULL LENGTH
SUPPORT
STRINGER
AT THIS POINT
13-5/8"
(346mm)
PROVIDE FULL
LENGTH SUPPORT
STRINGER
AT THIS POINT
60"
(1524mm)
7-3/4"
(197mm)
ROUGH FLOOR
BEDDING MATERIAL IS ACCEPTABLE
ROUGH FLOOR
BEDDING MATERIAL IS ACCEPTABLE