Installation Guide

753737-100 Rev. C
11
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
. All building materials and wiring should be routed away from the pump body and heater (if equipped).
WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
BLACK
WHITE
120 VA C
GND .
PUMP/MOTOR
WIRE SELEC TION GUIDE
Maxim um di stanc e fro m
fuseb ox to moto r
The s izes shown on t his
chart are recom menda tions
for c opper cond uctor s
only. Alw ays f ollow
local and natio nal
elect rical code s
Motor
Hi Pe rform ance
Ratin g
2.1 H .P.,
1.4 H .P.,
and 1 .25 H .P.
50' 100'
115V Power Line
150' 20 0 '
12 10 8 8
!
The whirlpool should be installed on a 120 vac,
15
amp dedicated
GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
Optional heater requires a separate 15 amp maximum GFCI circuit.
The whirlpool should be installed on a 120 vac, 20 amp dedicated
GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
Optional heater requires a separate 15 amp maximum GFCI circuit.
GFCI CIRCUIT REQUIREMENTS: FOR MODEL NUMBERS:
2422, 2425, 2645,
2771, 2805, 2908
ALL MODELS
7236, 2774
MODELS ENDING IN SUFFIX
LA, LAC, VA, VAC
6060, 2775, 2773, 2711, 2901
ALL MODELS
7236, 2774
MODELS ENDING IN SUFFIX
L, LC, V, VC
PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS: