Installation Guide

6
M965612 Rev. 1.7 (11/16)
!
Fig. 2
10a
11
7
2
2
Fig. 2b
2
3
1
6
9
FROM CONTROL BOX
WITH POWER SUPPLY
Fig. 2c
BLACK & WHITE
POWER
CONNECTIONS
15
13
CONNECTOR NOT
USED IN THIS
INSTALLATION
10b
14
4" CONTROL BOX
OR EQUIVALENT BY
OTHERS
12
Fig. 2a
16
7
6
9
810
2
PLUG INTO
WALL OUTLET
B
AC VERSIONS
(HARDWIRE / PLUG-IN); Fig. 2
NOTE: For AC installation, make power supply
connection before mounting CONTROL BOX (3) to wall.
1. Remove CONTROL BOX COVER (1). Fig. 2. Feed the
EXTENSION CABLES (2) from the Faucet through
the top of CONTROL BOX (3). Install CONNECTOR
LOCKING DEVICE (16). Fig. 2.
FOR PLUG-IN HOOKUP ONLY
2a. Insert POWER CORD (8) through POWER SUPPLY
GROMMET (9). Fig. 2a.
3a. Insert POWER CORD (8) through side GROMMET (6)
as shown. Fig. 2a.
4a. Connect SENSOR CABLES (2) to SOLENOID CABLE
(7) and POWER CORD (8). Connect it to the SINGLE AC
ADAPTER (10). Fig. 2a.
5a. Mount CONTROL BOX to wall. Replace CONTROL BOX
COVER (1). Tighten cover screws rmly.
Prior to making power connection, make sure
detection zone is not obstructed. Sensor is self
adjusting. Keep detection zone clear for 15 seconds
after power is connected.
6a. Plug AC POWER SUPPLY into wall outlet. Fig. 2a.
FOR HARDWIRE HOOK-UP ONLY
2b. Insert one end of the 10' EXTENSION (10a) through
POWER SUPPLY GROMMET (9). Fig. 2b.
3b. Insert 10' EXTENSION (10a) through side GROMMET
(6) as shown. Fig. 2b.
4b. Connect 10' EXTENSION (10a) to single terminal of
SINGLE AC ADAPTER (11). Fig. 2b.
5b. Connect EXTENSION CABLES (2) from Faucet Sensor
to SOLENOID CABLE (7) and to the terminal at the one
end of the SINGLE AC Adapter (11).
6b. Mount CONTROL BOX (3) to wall. Replace CONTROL
BOX COVER (1). Tighten cover screws rmly.
Contractor to supply CONTROL BOX (12) and power
to POWER SUPPLY (13).
7b. Mount POWER SUPPLY (13) into CONTROL BOX
(12). Connect White and Black connections to POWER
SUPPLY CONNECTIONS (14). Fig. 2c.
Prior to making power connection, make sure
detection zone is not obstructed. Sensor is self
adjusting. Keep detection zone clear for 15
seconds after power is connected.
8b. Connect the10' EXTENSION (10b) to the POWER
SUPPLY CABLE (15). Fig. 2c.
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
CAUTION
Before opening CONTROL BOX
disconnect AC power supply.
!