Specifications

754072-100 Rev. A
9
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Permit access for servicing blower as noted.
3. All building materials and wiring should be routed away from the air blower.
AIR BATH ELECTRICAL INSTALLATION INSTRUCTIONS
!
The air bath should be installed on a 120 vac,
15 or 20 amp
dedicated GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
GFCI CIRCUIT REQUIREMENTS: FOR MODEL NUMBERS:
2425L / V.168C-RHO 2422L / V.068C
2425L / V.268C-LHO 2645L / V.068C
2771L / V.068C 7236L / V.068C
PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS:
ELECTRONIC ACTIVATED AIR BATH (4 BUTTON PANEL)
120V, 60HZ
15A GFCI
ELECTRICAL
FEED
GFCI