Installation Guide

INSTALLATION INSTRUCTIONS
751777-100 Rev. G
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
SCALA™ CORNER
WHIRLPOOL/BATHING POOL
2664 SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
THANK YOU...
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any
shipping damage. If such damage is found, report it to
your vendor immediately.
After inspection and during installation, protect the bath
from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit
and check for leaks.
If a whirlpool, do not make modifications to the whirlpool
system or remove pump from factory mounting. This
could adversely affect the safety and performance of the
whirlpool and void the warranty. Do not handle or move
the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided
with the bath and must be ordered separately. Framing
and enclosing materials are provided by others. Check
for availability of optional American Standard wall tiling
bead (required for recess installations).
Protect all finished surfaces of the whirlpool during
construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping har-
ness at any time.
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFCI
Outlet
• Cement, Plaster,
Grout
NOTE: LEFT HAND MODEL SHOWN. FOR RIGHT HAND
MODEL, REVERSE DIMENSIONS
60 x 60 x 19-3/4 In. (1524 x 1524 x 502mm)
114 Lbs. ( 51 Kg.)
781 Lbs. (351 Kg.)
80 Gal. (303 L)
58 Gal. (220 L)
42 x 28 In. (1067 x 711mm)
60 x 40 In. (1524 x 1016mm)
14 In. (356mm)
37 Lbs./Sq.Ft. (182 Kgs./Sq.m)
41.7
68.5
GENERAL SPECIFICATIONS FOR 2664 WHIRLPOOL
1.1 HP, 9.9 AMPS,120V.
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
552mm
(21-3/4)
140mm (5-1/2)
1080mm
(42-1/2)
1524mm
(60) TYP.
1041mm
(41)
7
75
m
m
(3
0-1
/2)
PROVIDE ACCESS
FOR SERVICING
PUMP & CONTROLS
216mm
(8-1/2)
406mm
(16)
25mm (1)
INTEGRAL TILE
FLANGE (2) SIDES
19mm(3/4)
CUTOUT DIMENSION
1632mm
(64-1/4)
1505mm (59-1/4) TYP.
254mm X 254mm
(10 X 10) DRAIN
OUTLET CUTOUT
1600mm
(63-1/2)
1
3
56
m
m
(5
3
-3/8
)
OF DRAIN OUTLET
C
L
ROUGH
FLOOR
502mm
(19-3/4)
464mm
18-1/4
38mm
(1-1/2)
13mm (1/2)
INTEGRAL
TILE FLANGE
1-1/2" O.D. TAILPIECE
INTEGRAL
FEET
SUPPORT
LEVELING
STRINGER
(NOT FOR
SUPPORT)
1-1/2" N.P.T.M. THREADS
60mm
(2-3/8)
124mm
4-7/8
95mm
(3-3/4)
724mm (28-1/2)
ON/OFF
SWITCH
RECOMMENDED FITTING LOCATION
64 X 279mm (2-1/2 X 11)

Summary of content (4 pages)