User's Manual

INSTALLATION INSTRUCTIONS
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping
damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from
construction damage. Before installation, and before
enclosing with wallboard, tile, etc., water test the unit and
check for leaks.
If a whirlpool, do not make modifications to the whirlpool system
or remove pump from factory mounting. This could adversely
affect the safety and performance of the whirlpool and void the
warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the
bath and must be ordered separately. Framing and enclosing
materials are provided by others.
752562-100 Rev. H
© AS America, Inc. 2008
All product names listed herein are trademarks
of AS America, Inc. unless otherwise noted.
INTEGRAL APRON WITH
REMOVABLE ACCESS PANEL
FOR ABOVE-FLOOR
ROUGH INSTALLATION
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
COLONY™ 5 x 30 AFR
WHIRLPOOL/BATHING POOL
2740.XXX SERIES
GENERAL INSTALLATION INFORMATION
Bath may only be installed in a recess type installation.
Locate studs as required. Insure rough dimensions are proper, plumb and square. For whirlpools, access to pump/motor may be made through
access opening in apron panel. The following procedure must be used for all installations: leveling support stringer should be as indicated. This bath is
not self-supporting and must be supported along it's entire bottom. Support with mortar or grout.
Position bathtub/whirlpool within the recess, check level, front to back, side to side, and shim as necessary.
To secure the tub to wood studs use drywall screws w/washers or roofing nails immediately above the flange of the tub. To secure the tub to steel studs
use 4" drywall screws and flatwashers.
See page 2 for complete installation information.
Caution: Take extra care when driving nails or screws to avoid damaging the tub.
The tile or similar finished floor will be butted against the bottom of the tub apron, also holding the tub in place.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
IMPORTANT:
Water test unit before installation and enclosure!
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped
to you after careful inspection. The whirlpool version is completely
assembled with pump, motor, and system piping. All you need to
finish the installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from this product,
please follow the instructions and cautions.
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
GENERAL SPECIFICATIONS FOR 2740 WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP 1.1 HP, 9.9 AMPS,120V.
59-7/8 x 29-7/8 x 19-1/4 (1521 x 759 x 489mm)
105 Lbs. (47 Kgs.)
480 Lbs. (216 Kgs.)
45 Gal. (171 L)
38 Gal. (144 L)
20 x 46 (508 x 1168mm )
25-1/2 x 55-1/2(648 x 1410mm )
11-1/2 (292mm)
39 Lbs./Sq.Ft. (188 Kgs./Sq.m)
20.8
35.3
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
59-7/8
(1521mm)
29-7/8
(759mm)
WATER
RETENTION
FLANGE
(3 SIDES)
7
(178mm)
C/L OF DRAIN
1-1/2 (38mm)
(6) JETS
PUMP
FINISHED
WALL
3/4
(19mm)
C/L OF
SUPPLIES
HORIZONTAL TAILPIECE
ABOVE FLOOR OUTLET
1-1/2 O.D.
TAILPIECE
SEE FITTING
SPECS FOR
DIMENSIONS
(1) AIR VALVE
ON/OFF
SWITCH
ACCESS TO PUMP/MOTOR
THROUGH REMOVABLE
FRONT ACCESS PANEL
14-1/8
(359mm)
BATH SUPPORT
MATERIAL
19
(483mm)
7/8 WATER
RETENTION
FLANGE
(3 SIDES)
19-1/4
(489mm)
ROUGH
FLOOR
FINISHED
WALL
TOP OF
DECK
3
(76mm)
3-3/4
(95mm)
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
65 & 78
(1651 & 1981mm)
C/L OF
OVERFLOW
12
(305mm)
OPT.
4
(102mm)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
2-1/2
(64mm)
UNDERSIDE
OF DECK
LEVELING
STRINGER
NOT FOR
SUPPORT
TILING
FLANGE

Summary of content (4 pages)