INSTALLATION AND OPERATION MANUAL CHAMPION® WHIRLPOOLS AND AIR BATHS MODEL 6069LCH - CORNER MODEL 2771CH - 5' x 36" AIR BATH MODEL 2771LCH - 5' x 36" MODEL 7239LCH - 6' x 36" MODEL 2525LCH-LHO - 5' x 32" IA-LHO MODEL 2525LCH-RHO - 5' x 32" IA-RHO MODEL 2932LCH - 5' x 32" MODEL 2806LCH - 6' x 36" OVAL THANK YOU... for selecting an American Standard bathing product. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor and system piping.
TABLE OF CONTENTS: Safety Instructions...............................................................................Page 3 General Information.............................................................................Page 4 Optional Components..........................................................................Page 4 Specifications.......................................................................................Page 5 Roughing-in Reference....................................................
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS! ! WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision. ! WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting. ! WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within 60 inches (1524mm) of this unit.
General Installation Information Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc.
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR CHAMPION WHIRLPOOLS AND AIR BATHS Description Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF Rough-In Recess ExD Tub Edge to Centerline Overflow: J Weight with Water / Floor Loading Product Apron / Weight Mounting 6069LCH Corner* L 1949mm (76-3/4") W 1661mm (65-3/8") H 546mm (21-1/2") A 18" (457mm) B 13-3/4" (349mm) C 19-1/2" (495mm) Template Provided Templa
ROUGH-IN REFERENCES CHAMPION® XL 6' x 36" MODEL 7239LCH 72" (1829mm) 11" (279mm) 13-3/4" (349mm) 7-3/4" (197mm) 3"(76mm) 6" (152mm) 36" (914mm) CUT OUT IN FLOOR FOR DRAIN 36" (914mm) C/L OF OVERFLOW 21-1/2"(H) (546mm) 20-1/8"(A) (511mm) 20"(C) (508mm) DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1.2 AND A112.19.7.
ROUGH-IN REFERENCES CHAMPION® APRON 5' x 32" IA MODEL 2525LCH-RHO / MODEL 2525LCH-LHO (shown) 60" (1524mm) 13-1/2" (343mm) PUMP CUT OUT IN FLOOR FOR DRAIN 32" (813mm) 9" (229mm) 16" (406mm) 3" (76mm) 7-1/2" (191mm) 2-7/8" (73mm) 10-1/2" (267mm) C/L OF DRAIN OUTLET APRON IS PRIMARY ACCESS OPENING FOR MODELS 2525LCH-RHO/LHO ONLY.
ROUGH-IN REFERENCES CHAMPION® OVAL MODEL 2806LCH 11" (279mm) ON/OFF SWITCH 18" (457mm) 72" (1829mm) PUMP 9" x 13" (229 x 330mm) FLOOR CUTOUT 35-3/4" (908mm) INTEGRAL FITTING DECK 5-1/2" (140mm) C/L OF OVERFLOW PROVIDE ACCESS TO OUTLINE OF C/L OF PUMP FOR SERVICE CUTOUT DRAIN ON ALL INSTALLATIONS OVERFLOW 4-1/4" LEVELING STRINGER (108mm) (NOT FOR SUPPORT) 2" (51mm) INTEGRAL FEET SUPPORT 21-1/2" (546mm) 19-1/2" (495mm) ROUGH FLOOR 1-1/2" N.P.T.M. THREADS 1-1/2" O.D.
INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access opening. 1.
TYPICAL FLANGE MOUNTING DETAIL SUGGESTED WHIRLPOOL / BATH INSTALLATION METHOD WOOD STUDS TYPICAL INSTALLATION CORNER STUD WATERPROOF DRYWALL OR CEMENT BOARD TILE ROOFING NAIL SEALANT TUB 19-1/2 (495mm) 1 x 3 (25 x 76mm) WOOD STRINGER FULL LENGTH STEEL STUDS STEEL STUD WATERPROOF DRYWALL OR CEMENT BOARD WHIRLPOOL ACCESS PANEL WASHER TILE SEALANT TUB * SEE CUTOUT TEMPLATE PROVIDED 4" (102mm) DRYWALL SCREW 1 x 3 (25 x 76mm) WOOD STRINGER FULL LENGTH UNLESS AN ACCESS OPENING OF AT LEAST 12" x 2
WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. ! WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Grounding is required. The unit should be installed by a licensed electrician and grounded. 3.
OPERATION: NOTE: Each whirlpool is shipped from the factory with an air actuator on/off switch and pump with attached power supply cord. OPERATING THE SYSTEM WITHOUT WATER (DRY RUNNING) WILL CAUSE PUMP DAMAGE AND VOID THE WARRANTY. Always fill the whirlpool before operating the pump. The air switch is mounted either on the deck or side wall of the tub. 1. Fill the Whirlpool: Water level must be at least one inch (25mm) above the highest jet for proper operation. (See diagram below.
Lifetime® Drain Model 1599 (required on Models 2525LCH, 2771CH, 2771LCH, 7239LCH) Overflow: Partially fill tub, then enter tub before completely filling to prevent overflow. Toe Tap Drain: Depress drain cap to open or close drain. Access Panel (Model 2525LCH) Remove access panel to service motor.
DRAIN CONNECTION AND SYSTEM TEST Using recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain assembly instructions. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking.
AS AMERICA, INC. (AMERICAN STANDARD) LIMITED LIFETIME WARRANTY FOR CHAMPION® ACRYLIC WHIRLPOOLS & AIR BATHS AS America (“American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser.