Installation Guide
24
754818-100 Rev. A
OWNER’S MANUAL
WHIRLPOOL PUMP 
MOTOR WILL NOT START – CHECK FOR:
 •  Check the air line between the motor and air button for connection and depress to test air signal.
 •  Improper or loose connections, open switches or relays, blown circuit breakers.
 •  Manually check rotation of motor shaft for free movement and obstruction.
MOTORS CUTS OUT – CHECK FOR:
 •  Wiring, loose connections etc.
 •  Low Voltage at motor. (Frequently caused by undersized wiring.)
 •  Binding or overload. (Amperage Reading.)
MOTOR HUMS, BUT WILL NOT PRIME. –CHECK FOR:
 •  Make sure all suction, discharge lines and valves are open and un-obstructed.
 •  Check for correct water level.
 •  Block off suction and determine if pumps develops a vacuum. If pump develops a vacuum check
  discharge line for obstruction or a leak in the suction line.
 •  If the pump does not develop a vacuum and the pump has the correct water level, check for proper
  voltage and / or check the pump wet end for clogging or debris
AIR MASSAGE 
MOTOR WILL NOT START – CHECK FOR:
 •  Check the air line between the motor and air button for connection and depress to test air signal.
 •  Improper or loose connections, open switches or relays, blown circuit breakers.
 •  Manually check rotation of motor shaft for free movement and obstruction.
MOTORS CUTS OUT – CHECK FOR:
 •  Verify if the air supply line from the blower to the manifold is connected and not obstructed.
 •  Wiring, loose connections etc.
 •  Low Voltage at motor. (Frequently caused by undersized wiring.)
CHROMATHERAPY LIGHTS
LIGHTS WILL NOT OPERATE – CHECK FOR:
 •  Check the air line between the motor and air button for connection and depress to test air signal.
 •  Wiring and /or loose connections etc
 •  Improper or loose connections, open switches or relays, blown circuit breakers.
TROUBLE SHOOTING GUIDELINES 
(continued)