Installation Guide
   OWNERS MANUAL 
24
TROUBLE SHOOTING GUIDELINES 
Whirlpool Pump 
Motor Will Not Start – Check For: 
  Check the air line between the motor and air button for connection and depress to test air signal. 
  Improper or loose connections, open switches or relays, blown circuit breakers. 
  Manually check rotation of motor shaft for free movement and obstruction. 
Motor Cuts Out – Check For: 
  Wiring, loose connections etc. 
  Low Voltage at motor. (Frequently caused by undersized wiring.) 
  Binding or overload. (Amperage Reading.) 
Motor Hums, But Will Not Prime. –Check For: 
  Make sure all suction, discharge lines and valves are open and un-obstructed. 
  Check for correct water level. 
  Block off suction and determine if pumps develops a vacuum. If pump develops a vacuum check 
discharge line for obstruction or a leak in the suction line. 
  If the pump does not develop a vacuum and the pump has the correct water level, check for proper 
voltage and / or check the pump wet end for clogging or debris. 
Air Massage 
Motor Will Not Start – Check For: 
  Check the air line between the motor and air button for connection and depress to test air signal. 
  Improper or loose connections, open switches or relays, blown circuit breakers. 
  Manually check rotation of motor shaft for free movement and obstruction. 
Motor Cuts Out – Check For: 
  Verify if the air supply line from the blower to the manifold is connected and not obstructed. 
  Wiring, loose connections etc. 
  Low Voltage at motor. (Frequently caused by undersized wiring.) 
Chromatherapy Lights 
Lights Will Not Operate – Check For: 
  Check the air line between the control box and air button for connection and depress to test air 
signal. 
  Wiring and /or loose connections etc 
  Improper or loose connections, open switches or relays, blown circuit breakers. 