Specification

© 2016 AS America Inc.
spec_3341-3342_001_HuronBackSpud_EC Rev. D 9/16
M104
BARRIER FREE
HURON
®
BACK SPUD 1.6 gpf BOWL
WITH EVERCLEAN
®
VITREOUS CHINA
NOTES:
* VARIABLE — CHECK WITH MANUFACTURER OF FLUSHVALVE FOR PROPER ROUGH-IN DIMENSIONS.
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING NOT RECOMMENDED).
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON FLUSH VALVE, THE
PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING.
FLUSH VALVE NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI
Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for
use of superseded or voided pages.
FINISHED
WALL
FINISHED
FLOOR
24-7/8"
(632mm)
18-7/8"
(479mm)
16-7/8"
(429mm)
13-3/4"
(350mm)
11"
(279mm)
15-1/4"
(387mm)
4-1/4"
(108mm)
8-3/8"
(211mm)
6"
(150mm)
(2) SLOTS
1" x 1/2"
(25 x 13mm)
3" (76mm)
DIA. HOLE
IN WALL
6" (152mm)
DIA. HOLE
IN WALL
C/L OF SUPPLY
5-1/2"
(140mm)
C/L OUTLET
4-1/4"
(108mm)
10-3/4"
(273mm)
C/L of
1/2"(13mm)
DIA. HOLES
18-3/4"
(476mm)
21"