INSTALLATION AND OPERATION MANUAL MODEL 2664 MODEL 2934 MODEL 3572 MODEL 2709 MODEL 2935 MODEL 3573 MODEL 2711 MODEL 2938 MODEL 3574 MODEL 2742 MODEL 2939 MODEL 3575 MODEL 2748 MODEL 2940 MODEL 3581 MODEL 2806 MODEL 2941 MODEL 3582 MODEL 2903 MODEL 2942 MODEL 3583 MODEL 2908 MODEL 2943 MODEL 3584 MODEL 2932 MODEL 2944 MODEL 6060 MODEL 2933 MODEL 3571 MODEL 7236 BATHTUBS, WHIRLPOOLS, AIR BATHS AND COMBINATION TUBS WITH OPTIONAL CHROMATHERAPY THANK YOU...
TABLE OF CONTENTS: Cover................................................................................................Page 1 Table of Contents..............................................................................Page 2 Safety Instructions Notice.................................................................Page 3 Installation and Framing Instructions................................................Page 4 Roughing-in References for Recess Type Installations....................
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS! ! WARNING: Risk of personal injury. Do not permit children to use this bathtub without adult supervision. Never drop or insert any object into any opening. Do not operate this unit without the guard over the suction fitting. ! WARNING: Risk of electric shock. Do not permit electrical appliances near any bathtub when bathtub contains water. ! WARNING: Risk of hyperthermia and possible drowning.
Installation and Framing Instructions Each bath arrives ready for installation, completely equipped with the pump/blower electronics and plumbing necessary for operation. However, a drain/overflow kit is required for each bath and it is not included. The variety of installations for this bath may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square. ! ! ! ! ! 754532-100 Remove the bath from the carton.
ROUGH-IN REFERENCES FOR RECESS TYPE INSTALLATIONS C D 12" (305 mm) W E NOTE: FRONT EDGE OF BATH MUST BE SUPPORTED BY STUD WALL OR AMERICAN STANDARD APRON KIT LEVELING STRINGERS 24" (610 mm) ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR. ALLOW OPEN FRAMING ON PUMP/MOTOR END FOR SERVICE. ACCESS PANELS NOT REQUIRED FOR BATH TUBS UNLESS AN ACCESS OPENING OF AT LEAST 12" x 24" (305 x 610mm) IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
ROUGH-IN REFERENCES FOR PIER TYPE INSTALLATIONS AS DESIRED F CUTOUT G CUTOUT C 12" (305 mm) AS DESIRED MOUNTING SURFACE WATERPROOF SEALANT BATH 24" ( 10 mm) ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR. ALLOW OPEN FRAMING ON PUMP/MOTOR END FOR SERVICE. ACCESS PANELS NOT REQUIRED FOR BATH TUBS UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm) IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
SPECIFICATIONS: L W J H C SIDE VIEW A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR WHIRLPOOLS AND BATH TUBS Description Dimensions L-W-H Drain / Overflow 2 4 Scala Corner L 3-1/2" (2121mm) W 3-3/4" (1 1 mm) H 1 -3/4" (502mm) A 1 " (40 mm) B 13-1/4" (337mm) 270 Ellisse Oval ' L -1/4" (175 mm) W 3 -1/2" ( 7 mm) H 1 -3/4" (502mm) A 15" (3 1mm) B -7/ " (251mm) 2711 Ellisse ' x 4 " L 72" (1 2 mm) W 4 " (121 mm) H 21-1/2" (54 mm) A 1 -5/ " (422mm) B 12" (305mm) 2742 L 71-1
ROUGH-IN REFERENCES MODEL SERIES 2664 A C LO G m IN ) m " m) 05 TT m FI 7 m m) 0 4m 15 ( D " E x2 52 4m D (1 1/4 N ( 4 72 ( E " 5 MM 1" /2 1 -1 O C " x 2 E 2 R -1/ 2 TI O N 42-1/2" (10 0mm) 3-1/2" (1 00mm) 3-3/4" (1 1 mm) 4-1/4" (1 32mm) ) 1" (25mm) INTEGRAL TILE FLANGE (2) SIDES 10" x 10" (254mm x 254mm) DRAIN OUTLET CUTOUT 21-3/4" (552mm) " / m) -3 m 3 5 5 3 (1 -1/2" (21 mm) " /2 ) -1 mm 0 3 75 (7 3/4"(1 mm) CUTOUT DIMENSION 1 " (40 mm) CL OF DRAIN OUTLET 41" (1041mm) MODEL
ROUGH-IN REFERENCES MODEL SERIES 2711 72" (1 2 mm) OUTLINE OF CUTOUT 70-1/2" X 4 -1/2" (17 1 X 11 1mm) 3 -1/2" ( 27mm) 4" (102mm) 12" (305mm) C/L OF DRAIN " x 14" (22 x 35 mm) FLOOR CUTOUT 4 " (121 mm) RECOMMENDED FITTING LOCATION 2-1/"2 X 11" GRAB BAR FITTING AREA OPTIONAL DECK FITTING AREA PUMP PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS MODEL SERIES 2908 " (1 7 mm) 13" (330mm) 1 " (457mm) 3 " ( 14mm) 2-1/2" REF.
ROUGH-IN REFERENCES MODEL SERIES 2806 72" (1 2 mm) 11" (27 mm) 1 " (457mm) " x 13" (22 x 330mm) FLOOR CUTOUT 35-3/4" ( 0 mm) INTEGRAL FITTING DECK 5-1/2" (140mm) C/L OF DRAIN OVERFLOW OUTLINE OF CUTOUT MODEL SERIES 2903 0" (1524 mm) -1/2" (241 mm) 4-1/4" (1073mm) 12" (305mm) X "(22 mm) CUTOUT IN FLOOR FOR DRAIN 21-1/ " (537mm) 3" (7 mm) C L OF DRAIN OUTLET 754532-100 OUTLINE OF CUTOUT - USE TEMPLATE 10
ROUGH-IN REFERENCES MODEL SERIES 2742 4" (102mm) 35-3/4" (908mm) C/L OF DRAIN OUTLET 13-1/4" (337mm) 71-1/2" (1816mm) 3" (76mm) INTEGRAL FITTING DECK 2-1/4" X 14" (57 X 356mm) EDGE OF FLOOR CUTOUT BLOWER 41-3/4" (1060mm) PROVIDE ACCESS TO PUMP AND/OR BLOWER FOR SERVICE ON ALL INSTALLATIONS FLOOR CUTOUT 5" X 15" (127 X 381mm) 27-3/4 (705mm) 3/4" (19mm) PUMP OUTLINE OF SKID RESISTANT SURFACE OUTLINE OF CUTOUT 70" X 40-1/4" (1778 X 1022mm) MODEL SERIES 2748 59-3/4" (1518mm) 29-7/8" (759mm) IN
ROUGH-IN REFERENCES MODEL SERIES 6060 7 -3/4" REF.
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR STUDIO 5' X 32" WHIRLPOOLS AND BATH TUBS Description Deck Trim Option 2 32 Studio 5' x 32" Zero (5/ ") L 5 -1/2" (1511mm) W 31-1/2" ( 00mm) H 22-1/2" (572mm) 2 32 Studio 5' x 32" 2" 2 32 Studio 5' x 32" 2 33 Studio 5' x 32" w/Tile Flange Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF A 17-3/4" (451mm) B 10-3/4" (273mm) C 21-7/ " (55 mm) 5 " (1473mm) x 30" (7
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR STUDIO 5' X 36" WHIRLPOOLS AND BATH TUBS Description Deck Trim Option 2 34 Studio 5' x 3 " Zero (5/ ") L 5 -1/2" (1511mm) W 35-1/2" ( 02mm) H 22-1/2" (572mm) 2 34 Studio 5' x 3 " 2" 2 34 Studio 5' x 3 " 2 35 Studio 5' x 3 " w/Tile Flange Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF A 17-3/4" (451mm) B 10-3/4" (273mm) C 21-7/ " (55 mm) 5 " (1473mm) x 34" (
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR STUDIO 5-1/2' X 36" WHIRLPOOLS AND BATH TUBS Description Deck Trim Option 2 3 Studio 5-1/2' x 3 " Zero (5/ ") L 5-1/2" (1 4mm) W 35-1/2" ( 02mm) H 22-1/2" (572mm) 2 3 Studio 5-1/2' x 3 " 2" 2 3 Studio 5-1/2' x 3 " 2 3 Studio 5-1/2' x 3 " w/Tile Flange Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF A 17-3/4" (451mm) B 10-3/4" (273mm) C 21-7/ " (55 mm)
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR STUDIO 6' X 36" WHIRLPOOLS AND BATH TUBS Description Deck Trim Option 2 40 Studio ' x 3 " Zero (5/ ") L 71-1/2" (1 1 mm) W 35-1/2" ( 02mm) H 22-1/2" (572mm) 2 40 Studio ' x 3 " 2" 2 40 Studio ' x 3 " 2 41 Studio ' x 3 " w/Tile Flange Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF A 17-3/4" (451mm) B 10-3/4" (273mm) C 21-7/ " (55 mm) 70" (177 mm) x 34" (
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR STUDIO 6' X 42" WHIRLPOOLS AND BATH TUBS Description Deck Trim Option Dimensions L-W-H 2 42 Studio ' x 42" Zero (5/ ") L 71-1/2" (1 1 mm) W 41-1/2" (1054mm) H 22-1/2" (572mm) 2 42 Studio ' x 42" 2" 2 42 Studio ' x 42" 2 43 Studio ' x 42" w/Tile Flange Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF A 17-3/4" (451mm) B 10-3/4" (273mm) C 21-7/ " (55 mm) 70" (177 mm) x 40" (
SPECIFICATIONS: L W J H C SIDE VIEW A END VIEW DRAIN / OVERFLOW B GENERAL SPECIFICATIONS FOR STUDIO CORNER WHIRLPOOLS AND BATH TUBS Description Deck Trim Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF Rough-In Recess ExD Tub Edge to Centerline Overflow: J Weight with Water / Floor Loading Product Weight Gallon to Overflow Whirlpool Operating Volume 2 44 Studio Corner Zero (5/ ") L 3-15/1 " (2132mm) W 1-3/ " (155 mm) H 21-1/2" (54 mm) A 15" (3 1mm
SPECIFICATIONS: L W H SIDE VIEW J C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR GREEN TEA WHIRLPOOLS AND BATH TUBS Description Dimensions L-W-H Drain / Overflow 3571 Green Tea 5' x 3 " L 0" (1524mm) W 3 " ( 14mm) H 21" (533mm) A 1 " (40 mm) B 11-1/2" (34 mm) 3572 Green Tea 5-1/2' x 3 " L " (1 7 mm) W 3 " ( 14mm) H 21" (533mm) A 1 " (40 mm) B 11-1/2" (34 mm) 3573 Green Tea ' x 3 " L 72" (1 2 mm) W 3 " ( 14mm) H 21" (533mm) A 1 " (40 mm) B 11-1/2" (34 mm) 3574 Green Tea 5
ROUGH-IN REFERENCES MODEL SERIES 3571 0" (1524mm) 14-3/4" (375mm) 11-1/2" (2 2mm) 3 " ( 14mm) " (22 mm) CL CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 5 .5" x 34.5" (14 x 7 mm) MODEL SERIES 3572 " (1 7 mm) 14-3/4" (2 2mm) 11-1/2" (2 2mm) 3 " ( 14mm) " (22 mm) CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 4.5" x 34.
ROUGH-IN REFERENCES MODEL SERIES 3573 72" (1 2 mm) 14-3/4" (375mm) 11-1/2" (2 2mm) 3 " ( 14mm) " (22 mm) CL CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 70.5" x 34.5" (17 0 x 7 mm) MODEL SERIES 3574 0" (1524mm) 14-3/4" (375mm) 11-1/2" (2 2mm) 42" (10 7mm) " (22 mm) CL CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 5 .5 x 40.
ROUGH-IN REFERENCES MODEL SERIES 3575 72" (1 2 mm) 14-3/4" (375mm) 11-1/2" (2 2mm) 42" (10 7mm) " (22 mm) CL CUTOUT IN FLOOR FOR DRAIN OUTLINE OF CUTOUT 70.5 x 40.
ROUGH-IN REFERENCES MODEL SERIES 3582 " (1 7 mm) 33" ( 3 mm) " x 12" (227 x 305mm) FLOOR CUTOUT C/L DRAIN -3/4" (24 mm) 4-1/ " (105mm) OUTLINE OF CUTOUT 3 " ( 14mm) INTEGRAL FAUCET DECK 4" (102mm) MODEL SERIES 3583 " (1727mm) 34" ( 4mm) C/L DRAIN "x12" (227x305mm) FLOOR CUTOUT 11-1/2" (2 2mm) 4-7/ " (124mm) INTEGRAL FAUCET DECK 4-3/4" (121mm) OUTLINE OF CUTOUT OUTLINE OF SKID RESISTANT SURFACE USE CUT-OUT TEMPLATE SUPPLLIED WITH PACKAGED TUB 23 754532-100
ROUGH-IN REFERENCES MODEL SERIES 3584 72" (1 2 mm) 3 " ( 14mm) C/L DRAIN " x 12" (227 x 305mm) FLOOR CUTOUT 10-1/4" (2 0mm) 4-7/ " (124mm) 42" (10 7mm) INTEGRAL FAUCET DECK 754532-100 OUTLINE OF CUTOUT 24 OUTLINE OF SKID RESISTANT SURFACE
ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. ! WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Grounding is required. The unit should be installed by a licensed electrician and grounded. 3.
ELECTRICAL INSTALLATION INSTRUCTIONS (continued) ELECTRICAL FEED 120V, 0HZ 15A GFCI GFCI ELECTRONIC ACTIVATED AIR BATH (4 BUTTON PANEL) ELECTRICAL FEED 120V, 0HZ 15A GFCI GFCI ELECTRONIC ACTIVATED AIR BATH WITH LIGHTS (5 BUTTON PANEL) 754532-100 26
ELECTRICAL INSTALLATION INSTRUCTIONS (continued) ECOSILENT PUMP HAS P3JJ PLUG ELECTRICAL FEED 120V, 60HZ 15A GFCI GFCI ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL (1 BUTTON PANEL) ECOSILENT PUMP HAS P3JJ PLUG ELECTRICAL FEED 120V, 60HZ 15A GFCI GFCI ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL WITH LIGHTS (3 BUTTON PANEL) 27 754532-100
ELECTRICAL INSTALLATION INSTRUCTIONS (continued) USE THREE GFCI OUTLETS (USA MARKET) ELECTRICAL FEED 120V, 60HZ 20A GFCI (FOR HEATER) WHIRLPOOL HEATER IS FACTORY INSTALLED ON COMBINATION TUBS GFCI ECOSILENT PUMP HAS P3JJ PLUG ELECTRICAL FEED 120V, 60HZ 15A GFCI GFCI ELECTRICAL FEED 120V, 60HZ 15A GFCI GFCI ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL) 754532-100 28
ELECTRICAL INSTALLATION INSTRUCTIONS (continued) USE THREE JUNCTION BOXES (CANADA MARKET) ELECTRICAL FEED 120V, 60HZ 20A GFCI (FOR HEATER) GFCI White Black Green/Copper ELECTRICAL FEED 120V, 60HZ 15A GFCI GFCI ECOSILENT PUMP HAS P3JJ PLUG White Black Green/Copper ELECTRICAL FEED WHIRLPOOL HEATER IS FACTORY INSTALLED ON COMBINATION TUBS TO BOX 120V, 60HZ 15A GFCI GFCI TO BOX White Black Green/Copper ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL) 29 754532-100
ELECTRICAL INSTALLATION INSTRUCTIONS (continued) (HEATER) Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the AWG solid copper conductor supplied with the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3. HEATER ON E-Z INSTALL™ The conductor is secured to the lugs using set screws.
REMOTE BLOWER LOCATION OPTION IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular installation makes this effort practical. NOTE: Relocating blower motor from factory installed location, see photo 1, will require disassembly of air blower from mounting board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final desired position of air blower. Follow all instructions listed below.
REMOTE BLOWER LOCATION OPTION (continued) FOR THE COMBINATION WHIRLPOOL / AIR BATH CONFIGURATIONS ONLY: Up to two additional control box extensions (P/N 754512-0070A) are required as shown in photo 4 (below). Simply extend the cables going to the blower by adding in the extension cables. Be careful not to damage the cable connections and never plug in cables while power is applied to blower and/or pump. PUMP LONGER CONTROL PANEL CABLE (754025-0073A) CONTROL PANEL 4.
POST INSTALLATION CLEAN-UP Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface. Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water. Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
Operation: Single Speed Whirlpool AIR SWITCH ELECTRONIC SWITCH BATHING: • Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the optional EZ-Heater, it will automatically maintain the water temperature. • IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow. • IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump.
Operation: EcoSilent Whirlpool with Lights DISPLAY COLORS 1ST WHITE 2ND SLOW RAINBOW CYCLE 3TH FAST RAINBOW CYCLE 4TH TURQUOISE 5 BLUE TH 3-BUTTON ELECTRONIC SWITCH 6TH MAGENTA 7TH RED TH 8 ORANGE 9TH YELLOW 10TH GREEN 11 TH RETURN TO SLOW RAINBOW CYCLE BATHING: • Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the optional EZ-Heater, it will automatically maintain the water temperature.
Operation: Air Bath BATHING: • Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE • Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired. OPERATING AIR MASSAGE SYSTEM: ON/OFF: Press this button once to turn air-blower on. Press again to turn air-blower off. AIR SPEED INCREASE: Pressing this button will increase to the next higher speed. AIR SPEED DECREASE: Pressing this button will decrease to the next lower speed.
Operation: Air Bath with Lights BATHING: • Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE • Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired. OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM: ON/OFF: Press this button once to turn air-blower on. Press again to turn air-blower off. AIR SPEED INCREASE: Pressing this button will increase to the next higher speed. AIR SPEED DECREASE: Pressing this button will decrease to the next lower speed.
Operation: Air Bath with Lights (continued) EXITING THE BATH • Be sure to turn off the air blower before draining bath. • Open drain by rotating drain knob clockwise. DRYING CYCLE OPTIONS STANDARD DRYING CYCLE An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the purge cycle. 24H PROGRAMMABLE DRYING CYCLE The system must be stopped prior to activation or deactivation. Activation: Determine at which time you wish to purge to activate.
Operation: Combination Tub with Lights BATHING: • Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE • Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired. OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM: • Press this button to turn blower on. • Press this button again to turn blower off. • Press and hold button to increase blower speed. Release button at desired speed. • Press and hold button to decrease speed. Release button at desired speed.
Operation: Combination Tub with Lights (continued) EXITING THE BATH • Be sure to turn off the air blower before draining bath. • Open drain by rotating drain knob clockwise. DRYING CYCLE OPTIONS STANDARD DRYING CYCLE An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the purge cycle. 24H PROGRAMMABLE DRYING CYCLE The system must be stopped prior to activation or deactivation.
:PVS "NFSJDBO 4UBOEBSE XIJSMQPPM JT EFTJHOFE UP HJWF ZPV NBOZ ZFBST PG QMFBTVSF XJUI SFBTPOBCMF DBSF BOE NBJOUFOBODF :PVS OFX BDSZMJD CBUIUVC JT UPVHI EVSBCMF BOE FBTZ UP DBSF GPS 5IF DPMPST IBWF CFFO GPSNVMBUFE UP NBUDI PUIFS "NFSJDBO 4UBOEBSE GJYUVSFT BOE FOIBODF ZPVS DIPJDF PG CBUISPPN EFDPSBUJPOT 5IF IJHI HMPTT TVSGBDF XJMM SFUBJO JUT MBTUJOH MVTUFS XJUI QSPQFS DBSF BOE NBJOUFOBODF $-&"/*/( "/% .
AS America, Inc. Limited Lifetime Warranty for Premium Acrylic Air Baths AS America, Inc. (”American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser.