6
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
1
6
4
5
7
5
TEST INSTALLED FAUCET
Move HANDLE (1) down into "off" position.
With HANDLE (1) down in "off" position, pull HAND SPRAY (3)
from SPOUT (4). SPRAY (HOSE (5) should pull approximately 2 feet
and direct open SPRAY END (3) into sink.
Operate handle up and down, in COLD and HOT positions,
to flush water lines thoroughly.
Replace AERATOR (2). Place HAND SPRAY (3) back into FAUCET (4).
Check HAND SPRAY (3) operation:
With faucet on push BUTTON (6) for a broad cleansing
spray. BUTTON (6) will lock into this position.
If faucet drips, operate HANDLE several times from "off" to "on." Do not
apply excessive force.
Remove INDEX BUTTON (1), loosen HANDLE SCREW (2)
and remove HANDLE (3).
Unthread ESCUTCHEON CAP (4). Unthread three
MOUNTING SCREWS (5).
Lift CARTRIDGE (6) off MANIFOLD (7) and remove
CARTRIDGE SEALS (8).
Place SEALS (8) into CARTRIDGE PORTS (6a).
Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE
SCREW (1) and install INDEX BUTTON (2).
Test fitting.
Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).
Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING
SCREWS (5) alternately.
Remove AERATOR (2).
To unlock push opposite end of BUTTON (6). Faucet will
return to standard spray.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
2
3
1
2
3
4
5
6
8
7
6a