Installation Guide

- 2 -
3
M965789 (1/17)
Remove AERATOR. With handles in OFF position, turn
on water supplies and check all connections for leaks.
Operate both handles to ush water lines thoroughly.
Replace AERATOR.
TEST INSTALLED FAUCET
4
SERVICE
6
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
If Faucet Drips, Proceed As Follows:
T u r n HANDLES to OFF position.
If spout drips, operate HANDLES several times from OFF to ON position. Do not force HANDLES they turn only 90˚.
AERATOR may accumulate dirt causing distorted and reduced water ow. Remove AERATOR and clean before reinstalling.
Change Handle Direction:
Lift up HANDLE (1).
Remove Plastic ADAPTER (2) and CARTRIDGE NUT (3).
Lift and turn STOP WASHER 90˚.
Re-install HANDLE components.
To Change Cartridge:
Lift up HANDLE (1).
Remove Plastic ADAPTER (2) and CARTRIDGE NUT (3).
Lift CARTRIDGE (4) off PORT (5).
Clean CARTRIDGE (4) port.
Place CARTRIDGE (4) onto PORT (5) and tighten CARTRIDGE NUT (3) alternately.
Replace Plastic ADAPTER (2), HANDLE (1).
CAUTION
Turn off hot and cold water
supplies before beginning.
AERATOR
90°
90°
1
2
3
4
5
AERATOR