Specification Sheet

N16
© 2016 AS America Inc.
spec_6042.633 Decorum 0.125gpf HE Urinal Rev. 4/19
DECORUM
®
0.125 GPF
HIGH EFFICIENCY URINAL SYSTEM
SELECTRONIC
®
FLUSH VALVE
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so top of rim is 432mm (17") MAXIMUM from finished floor
.
NOTES:
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
IMPORTANT: Dimensions of xtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
*Note: The Critical Line (-C-L-)
on Vacuum Breaker must
typically be a minimum of
6" (152mm) above fixture.
Consult Codes for details.
VALVE LEFT or RIGHT HAND INSTALLATION
159mm
(6-1/4")
547mm
(21-1/2")
REF.
483mm
(19")
396mm
(15-9/16")
102mm
(4")
C/L OF
OUTLET
338mm
(13-5/16")
8mm x 25mm
(5/16" x 1")
SLOT
FINISHED FLOOR
2" N.P.T.
FEMALE OUTLET
CONNECTION
13mm
(1/2")
271mm
(10-11/16")
356mm
(14")
419mm
(16-1/2")
MAX
610mm
(24")
OPTIONAL
45mm
(1-3/4")
45mm
(1-3/4")
3/4"
SPUD
191mm
(7-1/2")
FINISHED
WALL
57mm
(2-1/4")
DETECTION ZONE
400mm-800mm
(15-3/4" TO 31-1/2")
15˚
419mm
(16-1/2")
SUPPLY
DN 20mm
(3/4" I.P.S.)
108-133mm
(4-1/4" to 5-1/4")
293mm
(11-1/2")
MANUAL
OVERRIDE
BUTTON
*CRITICAL LEVEL
-C-L-
K2 HANGERS
Fixture Compliance Certications -
Meets or Exceeds the Following Specications:
ASME A112.19.2-2008/CSA B45.1-08 for Vitreous
China Fixtures
Valve Listings:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
BARRIER FREE