Installation Guide

RECOMMENDED TOOLS; Fig. 2
Fig. 2
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Teflon Tape
Flat Blade Screwdriver (For adjusting Supply Stop)
Adjustable Wrench
Tape Measure
Hacksaw
Tubing Cutter
File
For Sweat Connection; Solder and Torch
2.5mm Hex Wrench
1.5mm Hex Wrench
1
2
3
4
5
6
7910
8
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
• Flush all water lines prior to operation (See Step 5). Dirt
and debris can cause flush valve to run continuously.
With the exception of Supply Stop Inlet, DO NOT use
pipe sealant or plumbing grease on any valve component
or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see “Care and Cleaning”
section of this manual.
This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valves performance.
IMPORTANT:
All plumbing must be installed in accordance with
applicable codes and regulations.
The use of water hammer arrestors is strongly
recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
Water supply lines must be sized to provide an
adequate volume of water for each fixture.
2
Fig. 1
Roughing-in Dimensions
GENERAL DESCRIPTION:
10'
Exposed Flushometer
for 3/4" Top Spud Fixtures
MANUAL FLUSH VALVE, 0.5 GPF
-C-L-
152mm
(6)
(Min.)
M965360 REV. 1.9 (5/19)
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" (152mm) minumim above fixture.
Consult Codes for details.
*CRITICAL
LEVEL
SUPPLY
DN 19mm
(3/4" I.P.S. For 3/4" Top Spud)
108mm-133mm
(4-1/4" to 5-1/4")
295mm
(11-1/2")
FINISHED WALL
3/4" VACUUKM
BREAKER SHOWN
135mm
(13-1/2")
38mm-127mm
(1-1/2-5")
-C-L-
Exclusive, self cleaning piston-operated
flush valve.
OPERATING PRESSURE:
Overall Range: 20-125 psi **
Recommended: 20 psi (flowing)-
80 psi (static)
FLOW REQUIREMENT:
10gpm (37.9 L/min).
**Water pressure over 80 psi is not
recommended with most
plumbing fixtures
See (Section 8) for converting Flush
Valve to Left Hand Installation.
Right or Left Hand Installation