Specification Sheet

MANUAL URINAL FLUSH VALVE
WITH SIDE-MOUNT OPERATOR
© 2019 AS America Inc.
7/19
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" (152mm) minimum above fixture.
Consult Codes for details.
Right or Left Hand Installation
Roughing-in Dimensions
-C-L-
152 mm
(6)
(Min.)
*CRITICAL
LEVEL
SUPPLY
DN 19 mm
(3/4" I.P.S.
For 3/4"
Top Spud)
108 mm-133 mm
(4-1/4" to 5-1/4")
147 mm
(5-13/16")
295 mm
(11-1/2")
253 mm
(9-15/16")
FINISHED WALL
3/4" VACUUKM
BREAKER SHOWN
135 mm
(13-1/2")
38 mm-127 mm
(1-1/2-5")
-C-L-
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND
USABLE BUILDING FACILITIES-CHECK LOCAL CODES
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
INCLUDES:
• 3/4" I.P.S. angle stop with back-ow prevention and
vandal-resistant cap
Sweat solder kit including cover tube and wall ange
High back pressure vacuum breaker with down tube
Spud coupling & ange for 3/4" top spud
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" (152mm) minimum above fixture.
Consult Codes for details.
FOR 1-1/2" TOP
SPUD FIXTURES
-C-L-
*CRITICAL
LEVEL
SUPPLY
DN 25 mm
(1" I.P.S.)
295 mm
(11-1/2")
ROUGH-IN
DIMENSION
FINISHED WALL
135 mm
(13-1/2")
38 mm-127 mm
(1-1/2-5")
Installation à gauche ou à droite
152 mm
(6")
(Min.)
147 mm
(5-13/16")
253 mm
(9-15/16")
Roughing-in Dimensions
108 mm-133 mm
(4-1/4" to 5-1/4")