Specification Sheet

L3
Revised (5/16)
© 2016 AS America Inc.
MODEL NUMBER:
6047.111.002 Flush Valve for 11-1/2" Supply C\L
to top of bowl, 1.1 gpf
NOTICE:
To ensure proper performance, this 1.1 gpf (4.2 Lpf)
Toilet Flush Valve must be installed on a ushom-
eter bowl that is certied (per ASME A112.19.2/CSA
B45.1) to operate at 1.1 gpf (4.2 Lpf).
OPERATING PRESSURE:
25 psi (owing)-80 psi (static)
FLOW REQUIREMENT:
25gpm (94.6 L/min.)
MaP* Score
• 1,000 grams of miso @ 1.1 gpf (when used with
an American Standard Afwall Millenium or Madera
universal ushometer bowl)
*Maximum Performance (MaP) testing performed by IAPMO R&T Lab.
MaP Report conducted by Veritec Consulting, Inc. and Koeller and
Company.
MANUAL FloWise
®
EXPOSED TOILET FLUSH VALVE
1.1 GPF
FINISHED WALL
FINISHED
FLOOR
73mm
(2-7/8")
343mm
(13-1/2")
TYPICAL WATER CLOSET INSTALLATION:
AFWALL™ TOILET SHOWN
295mm
(11-1/2")
-C-L-
SEE ROUGH-IN
ON BACK
CRITICAL
LEVEL
121mm,
+/-13mm
(4-3/4")(+/-1/2")
SUPPLY
DN 25mm
(1" I.P.S.)
RECOMMENDED SPECIFICATION:
Manual toilet flush valve shall feature self-cleaning brass piston valve with integral wiper spring in refill orifice to prevent clogging. Valve
remains closed and does not need to be reset after loss of water pressure. Includes cast brass valve body and cover with chrome finish and
vandal resistant stop cap. Includes sweat solder kit with wall flange and cover tube. High back pressure vacuum breaker and angle stop with back-flow
protection and vacuum breaker included. 1.1 gpf / 4.2 Lpf Flush valve shall be American Standard Model # 6047.111.002.
GENERAL DESCRIPTION:
Manual Piston-Type Water Closet Flush Valve for
oor-mounted or wall-hung 1-1/2" top spud bowls.
INCLUDES:
1" I.P.S. angle stop with back-ow prevention and
vandal-resistant cap
• Sweat solder kit including cover tube and wall ange
• High back pressure vacuum breaker with down tube
• Spud coupling & ange for 1-1/2” top spud
PRODUCT FEATURES:
Self-cleaning brass piston with integral wiper spring
prevents clogging and reduces maintenance
Piston operation delivers superior ush accuracy and
repeatability
Piston valve remains closed and does not need to be
reset after loss of water pressure
Non-hold open handle provides automatic shut-off
after every ush
Fail-Safe Operation: Valve automatically closes and
does not need to be reset, on loss of water pressure
Positive seal ensures leak-free performance
No external volume adjustment
Durable chrome-plated cast brass construction
is ideal for commercial applications
Chemical-resistant EPDM seals for long life
Adjustable tailpiece for rough-in exibility
Can be installed left or right handed
ADA complaint