Installation Guide

3
M965022 Rev. 2.2 (5/19)
1
2
3
4
5
6
7 9 10
8
10'
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" (152mm) minimum above fixture.
Consult Codes for details.
FOR 1-1/2" TOP
SPUD FIXTURES
-C-L-
*CRITICAL
LEVEL
SUPPLY
DN 25 mm
(1" I.P.S.)
108-133 mm
(4-1/4" to 5-1/4")
292 mm
(11-1/2")
6047.121
ROUGH-IN
DIMENSION
686 mm
(27")
6047.122
ROUGH-IN
DIMENSION
610 mm
(24")
6047.117
ROUGH-IN
DIMENSION
FINISHED WALL
6047.122
735 mm
(29")
6047.117
660 mm
(26")
6047.121
135 mm
(13-1/2")
38mm-127mm
(1-1/2-5")
Right or Left Hand Installation
152 mm
(6
")
(Min.)
Roughing-in Dimensions
Fig.1
Fig.2
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic
®
Flush Valve
the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
IMPORTANT:
All plumbing must be installed in accordance with
applicable codes and regulations.
The use of water hammer arrestors is strongly
recommended for commercial applications. All
piping behind the walls should be properly secured
and fastened.
Water supply lines must be sized to provide an
adequate volume of water for each xture.
Flush all water lines prior to operation
(See Step 5). Dirt and debris can cause ush
valve to run continuously.
With the exception of Supply Stop Inlet,
DO NOT use pipe sealant or plumbing grease
on any valve component or coupling!
Protect the chrome or special nish on the
Flushometer. DO NOT USE toothed tools on
nished surfaces to install or service these
valves. Also see “Care and Cleaning” section
of this manual.
This product contains mechanical and/or
electrical components that are subject to
normal wear. These components should be
checked on a regular basis and replaced as
needed to maintain the valves performance.
GENERAL DESCRIPTION
MANUAL FLUSH VALVE
Exposed Flushometer
for 1-1/2" Top Spud Fixtures
OPERATING PRESSURE:
• Overall Range: 20-125 psi **
Recommended: 25 psi (owing)
80 psi (static)
FLOW REQUIREMENT:
• 25gpm (94.6 L/min).
** Water pressure over 80 psi is not
recommended with most plumbing xtures
RECOMMENDED TOOLS; Fig. 2
1. Teon Tape
2. Flat Blade Screwdriver (For adjusting Supply Stop)
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench
See (Section 8) for converting
Flush Valve to Left Hand Installation.