Installation Guide

4
M965652 Rev. 1.9 (3/19)
2
MOUNT CONTROL BOX; Fig. 2
1. Determine location of CONTROL BOX (1). It must be located
with-in the 14" (356mm) by 21" (533mm) shaded area shown
in Figure 2 in order for electrical connections from the spout
assembly to be made.
NOTE: CONTROL BOX SUPPLY HOSE IS 20". DISTANCE
BETWEEN WALL SUPPLY AND ENCLOSURE (1)
MUST BE TAKEN INTO CONSIDERATION.
2. Remove tape from CONTROL BOX COVER (2) and pull off
COVER (2). Hold the CONTROL BOX (1) in desired
location and mark the four mounting hole locations as
shown.
NOTE: Find plastic bag containing 4 M5X16 screws to be
used for securing the CONTROL BOX COVER (1)
when installation is complete.
NOTE: For AC installation, make power supply connection
before mounting CONTROL BOX (1) to wall.
3. It is recommended that the CONTROL BOX (1) be
secured to a wall stud or cross brace within the wall using
the SCREWS (3) supplied. If the CONTROL BOX (1) is to
be installed on tile or plaster walls, the ANCHORS (4) and
SCREWS (3) should be used.
3
CONNECT SPOUT HOSE TO CONTROL BOX;
Fig. 3
1. Connect SUPPLY NUT (1) from spout hose to nipple on top
of ENCLOSURE (2). Tighten with adjustable wrench to make
a water tight connection. Fig. 3.
4
CONNECT WATER SUPPLY TO CONTROL
BOX AND WALL SUPPLY; Fig. 4, 4a
NOTE: If using the optional Mixing Valve, see sheet
#M968808 for installation instructions.
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on
CONTROL BOX (2).
2. Connect FLEXIBLE SUPPLY HOSE (3) to SUPPLY NUT (1)
on CONTROL BOX (2). Tighten to make a water tight
connection. Use two wrenches to tighten if necessary. Fig. 4.
3. Connect FLEXIBLE SUPPLY HOSE (3) directly to wall
supply. Connection on FLEXIBLE SUPPLY HOSE (3) is 3/8"
compression. Use adjustable wrench to tighten connection.
Do not over tighten. Fig. 4a.
Note: FLEXIBLE SUPPLY HOSE (3) measures 20" from
the bottom of the CONTROL BOX (2) base. If additional
supply length is required, installer must purchase parts
separately.
Impor tant: If FLEXIBLE SUPPLY HOSE (3) is too long, loop to
avoid kinking.
Fig. 2
14"
(356mm)
3-3/4"
(96mm)
2-3/4"
(71mm)
3"
(76mm)
21"
(mm)
2
4
3
1
1
1
20"
(500mm)
MOUNTING HOLES
SUPPLIES
WASTE
ENCLOSURE
MOUNTING
HOLES
LAVATORY RIM OR
MOUNTING SURFACE
Fig. 3
1
2
1
3
3
Fig. 4
2
COLD WATER OR
TEMPERED
WALL SUPPLY
Fig. 4a
4