MULTI-AC VERSION (DAISY-CHAIN); Fig. 3, 3a
Important: All control box covers must be removed before beginning to make daisy-chain connections.
Disconnect the rst units Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 5).
For subsequent Units, refer to instructions below...
1. Remove COVERS from all CONTROL BOX (3).
2. Insert pervious unit’s 10’ EXTENSION (11a) through
gray GROMMET (5b) and connect to single terminal of
Y-ADAPTER (11).
3. Remove solid black plug grommet from left side of all
CONTROL BOX (3), and replace with GRAY
GROMMET (5b). (Supplied with each Faucet).
4. Feed CABLES (2) through the top of CONTROL BOX (3).
Connect one CABLE (2) to the SOLENOID CABLE (7),
and the other to either of the two available terminals of
the Y-ADAPTER (11). Connect the current unit’s 10'
EXTENSION (10a) to available terminal of the
Y-ADAPTER (11).
5. Feed the other end of the 10 ft. EXTENSION (10b)
through the two GRAY GROMMETS (6a and 6b) and
connect to the single terminal of the next unit’s
Y-ADAPTER (11). Place Y-ADAPTER (11) into
CONTROL BOXT (3).
6. Repeat Steps above for each additional Unit, for a
Max. of 15 Units on one AC POWER SUPPLY.
7. Reinstall CONTROL BOX COVERS. Tighten cover
screws rmly.
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or
modifying any components will void the warranty.
Unit #2 Detail
Fig. 3a
5
5b
10b
6a
6b
10a
7
2
2
11
11a
3
Unit #2 Unit #3
Fig. 3
10 ft.
EXTENSION
CABLE
AC POWER
SUPPLY
*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
OR
Unit #1
Already installed
BLACK &
WHITE
POWER
CONNECTIONS