Selectronic Remote Control Operating Manual Software Version 1.6 M965370 REV. 1.
Transmission Area DISPLAY Mini-SUB Port OPERATION: The remote programmer has 4 keys: “Enter” or validate “Cancel” “Scroll UP” “Scroll Down” The ‘Down’ Key is also used to turn “ON” the remote programmer. After not being used for 2 minutes, the programmer automatically turns itself off.
Setting The Detection Distance *** ONLY DONE AFTER SELECTING ALL THE MODE SETTINGS *** When using the programmer, the sensor will begin blinking for approximately 5 seconds after the “ENTER” key is pressed and the display shows “TRANSMISSION OK”. While it is blinking move your finger to within 1 inch of the sensor (nearly covering it). When the light stops blinking and stays on steady, remove your finger and, with the palm of your hand facing the sensor, move your hand to the distance to be set.
Start Cleaning ON Disinfection Press to turn on the programmer (Version VI.6 will display) Diagnostics Press to activate the menus TIP: Cleaning – Use this mode to disable the sensor for 1 minute. This is sometimes used by the cleaning crew to keep the faucet “off” while cleaning the fitting and or fixture.
Parameter SENSOR 2018 URI. & WC Language From MENU 3 SENSOR 2018 FAUCET MENU 4 PARAMETER Backlight NEXTGEN SENSOR 2016 VERSION MENU 5 PARTIAL COUNT Align the programmer with the sensor and press to transmit the program to the sensor. Align the programmer with the sensor and press to transmit the program to the sensor. MENU 7 BATTERY VOLTAGE Align the programmer with the sensor and press to transmit the program to the sensor.
NOTE: This is the standard ʻinstant on / instant offʼ faucet mode. From MENU 4 Press to set MENU 4.1 HAND-WASHER COMF. TIMEOUT = 1 Sec. Press up or down to adjust time SAFETY TIMEOUT = 55 Sec. Hand-Wash Setting the sensor to the Hand-Wash faucet mode: - Set the "Comfort Timeout" - Set the "Safety Timeout" - Set "Auto-Rinse" frequency (if the frequency is set to 0, “auto-rinsing” (auto-purging) is Off) - Set the "Duration" (run time) of the auto-rinsing process. TIP: The “COMF.
Metering -- Faucet From MENU 4.1 COMF. TIMEOUT = 15 Sec. (RUN TIME) Press up or down to adjust metering run time MENU 4.2 METERING Setting the sensor to the Metering faucet mode: - Set the "Comfort Timeout" (run time) - Set "Auto-Rinse" frequency (if the frequency is set to 0, ‘auto-rinsing” (auto-purging) is Off) - Set the "Duration" (run time) of the auto-rinsing process. TIP: In this Metering Mode, the “COMF.
NOTE: This is actually uses the ‘Metering’ mode, but with the added feature of being able to start and stop the water flow before the metering time runs out. From MENU 4.2 COMF. TIMEOUT = 15 Sec. Press up or down to adjust metering run time MENU 4.3 ON/OFF Auto. RINSE = OFF.
Urinal -- Urinal Flush Valve TIP: The "DETEC. INTERVAL" (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Recommended setting is 5 sec. From MENU 4 MENU 4.
Flushometer – Toilet Flush Valve TIP: The "DETEC. INTERVAL" (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Recommended setting is 5 sec. From MENU 4 DETEC INTERVAL = 5 Sec MENU 4.6 FLUSHOMETER * REFER TO PAGE 12 FOR RECOMMENDED SETTINGS TIP: A large amount of water is delivered after a pre-programmed number of flushes (or time) to prevent the drain from clogging.
Dual Flush – Toilet Flush Valve From MENU 4 MENU 4.8 Dual FlushToilet TIP: The "Short Rinsing" is the is the flush time used when the user stays in the detection zone for less than 1 minute. – This should be the setting for the lowest of the 2 flush volumes listed for this model flush valve. – See Flush Valve Settings Chart *SHORT RINSING = 1.5 Sec Press up or down to adjust duration * REFER TO PAGE 12 FOR RECOMMENDED SETTINGS DETEC INTERVAL = 5 Sec TIP: The "RINSE START INT.
OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) 4 OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments)