Dimensions Guide

© 2019 AS America Inc.
12/19
Roughing-in Dimensions
114 mm
(4-1/2")
72 mm
(2-7/8")
57 mm
(2-1/4" MIN.)
DETECTION ZONE
400 mm-800 mm
(15-3/4" TO 31-1/2")
SUPPLY
DN 25 mm
(1” I.P.S.)
15˚
FINISHED WALL
108 -134 mm
(4-1/4" TO 5-1/4")
Right or Left Hand Installation
FOR 1-1/2" TOP
SPUD FIXTURES
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" (152 mm) above fixture. Consult
Codes for details.
406 mm
(16")
292 mm
(11-1/2")
MANUAL
OVERRIDE
BUTTON
Roughing-in Dimensions
116 mm
(4-5/8")
72 mm
(2-7/8")
57 mm
(2-1/4" MIN.)
DETECTION ZONE
400 mm-800 mm
(15-3/4" TO 31-1/2")
SUPPLY
DN 25 mm
(1” I.P.S.)
15˚
FINISHED WALL
115 mm-134 mm
(4-1/2" TO 5-1/4")
FOR 1-1/2" TOP
SPUD FIXTURES
6065.122
799 mm
(31-1/2")
6065.121
409 mm
(16-1/8")
293 mm
(11-1/2")
MANUAL
OVERRIDE
BUTTON
6065.121
ROUGH-IN
DIMENSION
683 mm
(27")
6065.122
ROUGH-IN
DIMENSION
-C-L-
*CRITICAL
LEVEL
6065.121
6065.122
-C-L-
*CRITICAL
LEVEL
165 mm
(6-1/2")
565 mm
(22-1/4")
Right or Left Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" (152mm) above fixture. Consult
Codes for details.
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
NOTICE:
To ensure proper performance, this 1.1 gpf
(4.2 Lpf) Toilet Flush Valve must be installed on
a ushom eter bowl that is certied (per ASME
A112.19.2/CSA B45.1) to operate at 1.1 gpf
(4.2 Lpf).
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND
USABLE BUILDING FACILITIES-CHECK LOCAL CODES
SUPPLY
DN 25 mm
(1" I.P.S.)
108 - 134 mm
(4-1/4" - 5-1/4")
FINISHED WALL
FINISHED
FLOOR
73 mm
(2-7/8")
419 mm
(16-1/2")
TYPICAL WATER CLOSET INSTALLATION:
AFWALL
®
TOILET SHOWN
293 mm
(11-1/2")
-C-L-
SEE ROUGH-IN
ON BACK
CRITICAL
LEVEL
Ultima Selectronic
®
Exposed Toilet Flush Valve
Piston-Type
Battery-Powered