Specification Sheet

L285
Revised
© 2013 AS America Inc.
TRAP PRIMER
FOR EXPOSED, TOP SPUD TOILET FLUSH VALVES
GENERAL DESCRIPTION:
Durable brass construction. Tr ap primer diverts a small
amount of water from each flush to the floor drain to maintain
a constant water seal, preventing sewer gases from escaping
into the air. Water Deflector controls the amount of water
diverted to the drain. This trap primer will deliver excellent
flushing performance at 1.28 gpf (4.90 Lpf) when used with an
American Standard 1.28 gpf flushometer valve & bowl. Piping
from trap primer to floor drain by other.
PRODUCT FEATURES:
Durable brass construction.
Diverter controls the amount of water diverted to the floor drain.
• Excellent flushing performance at 1.28 gpf when installed
with an American Standard flushometer valve & bowl.
• Includes vacuum breaker, down tube, diverter, 3/8" elbow
coupling and flexible tube from trap primer to wall.
• Includes wall flange and coupling kit to connect tubing to
1/2" NPT pipe.
MODEL NUMBER:
6065.830.002 Trap Primer
For exposed, top spud toilet flush valves.
C L
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" (152mm) minimum above fixture.
Consult Codes for details.
-C-L- -C-L-
*CRITICAL
LEVEL
295mm
(11-1/2") REF.
25mm
(1")
ROUGH-IN
DIMENSION
FLOOR DRAIN
FINISHED WALL
51mm
(2" MIN.)
152mm
(6")
(Min.)
57mm (2-1/4")
(CENTER OF
MARK) CRITCAL
LINE TO OUTLET
70mm
(2-3/4") DIA.
1/2"-14 NPT MALE PIPE FOR TRAP
PRIMER OUTLET (NOT SUPPLIED)
DIMENSION
TO BE DETERMINED
BY INSTALLER