Installation Instructions

8
M965645 EN REV. 2.2 (10/19)
CAUTION: Use only American Standard supplied transformers
and cable sets. Using non-AS supplied cables, or cutting,
splicing or modifying any components will void the warranty.
Fig.10b
1
2a
2
*MAXIMUM OF 15 UNITS PER TRANSFORMER.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
3
Unit #1 Unit #2 Unit #3
Already installed
(See electrical installation
instructions, page 5)
BLACK & WHITE
POWER
CONNECTIONS
8b
MULTI-AC VERSION (DAISY-CHAIN); Fig. 10b.
Important: All cover plates must be uninstalled before beginning to make daisy-chain connections.
Disconnect the rst unit’s Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section #7 & #8a (page 5).
For subsequent Units, refer to section #7 (page 5), as well as instructions below...
1. Connect one end of the 27" EXTENSION CABLE (1) to one of the two available terminals on the one end of the
Y-ADAPTER (2).
2. Take the 10' EXTENSION (3) and connect one end to the single terminal of Y-ADAPTER (2), and
the other end to available terminal of the previous unit’s Y-ADAPTER (2a).
3. Repeat process for each subsequent unit.
4. Place Y-ADAPTERS (2) into respective electrical box.
5. Reconnect the rst unit’s Y-ADAPTER (2a) to power supply once all daisy-chain unit connections have been made.
CAUTION
Ensure that the line power to bathroom
is OFF prior to making connections.