Technical Specifications

© 2018 AS America Inc.
6/18
SELECTRONIC
®
SENSOR-OPERATED
TOILET FLUSH VALVE
HARD-WIRED AC POWER, BASE MODEL
Roughing-in Dimensions
Right or Left Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" min. (152 mm) above fixture.
Consult Codes for details.
TOP OF
FIXTURE
406 mm
(16")
292 mm
(11-1/2")
-C-L-
114 mm
(4-1/2")
86 mm
(3-3/8")
72 mm
(2-7/8")
DETECTION ZONE
400 mm-800 mm
(15-3/4" TO 31-1/2")
2-GANG ELECTRICAL
BOX BY OTHERS
SUPPLY
DN 25mm
(1" I.P.S.)
15˚
FINISHED WALL
51 mm (2") HOLE
FOR CONDUIT
108 mm-134 mm
(4-1/4" TO 5-1/4")
FOR 1-1/2" TOP
SPUD FIXTURES
MANUAL
OVERRIDE
BUTTON
*CRITICAL
LEVEL
45
˚
180
˚
305 mm
(12" MAX.)
160 mm
(6-1/4")
160 mm
(6-1/4")
57 mm (2-1/4") -
137 mm (5-3/8")
OPTIONAL COVER PLATE
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Meets the American Disabilities Act Guidelines
and ANSI A117.1 Requirements for accessible
and usable building facilities - check local codes