Installation Instructions

3
Roughing-in Dimensions (Front Installation Shown)
Right or Left Hand Installation
See (Section 5) for converting Flush
Valve to Left Hand Installation.
1. Installation Instructions
2. Flush Valve Body Assembly
3. Vacuum Breaker Tube
4. Spud Coupling Nut and Washers
5. Spud Flange
6. Wall Escutcheon
7. Cover Tube
8. Sweat Adapter
9. Stop Valve
GENERAL DESCRIPTION:
SELECTRONIC
®
PROXIMITY TOILET
FLUSH VALVE for 1-1/2" Top Spud Fixtures
M965644 EN REV. 2.3 (10/19)
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
SEE DETAIL “A
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
" (152mm) above
fixture. Consult Codes for details.
406 mm
(16")
292 mm
(11-1/2")
*-C-L-
-C-L-
114 mm
(4-1/2")
86 mm
(3-3/8)
73 mm
(2-7/8")
DETECTION ZONE:
400 - 800 mm (15-3/4" – 31-1/2")
(FACTORY SETTING: 600 mm (23-5/8")
(1" NPT)
FINISHED WALL
51 mm (2") HOLE
FOR CONDUIT
MANUAL
OVERRIDE
BUTTON
305 mm MAX.
(12" MAX.)
TOP OF
FIXTURE
152 mm MIN.
(6") MIN.
170 mm MAX.
(6-11/16") MAX.
108 - 134 mm
(4-1/4" – 5-1/4")
15˚
FINISHED TILE WALL
FINISHED PLASTER WALL
DETAIL “A
4" (102 mm) SQ. x 3-1/2" (89 mm) DEEP ELECTRICAL BOX
Hubbel-RACO #256 OR EQUAL (BY CONTRACTOR).
4" (102 mm) SQ. BOX DEVICE COVER (PLASTER RING).
3/4" (19 mm) HIGH Hubbel-RACO #779 OR EQUAL
(BY CONTRACTOR).
NOTE: INSTALL PLASTER RING SO THAT SCREW