Specification

LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Ultima
Manual Toilet Flush Valve
Diaphragm-Type
1.6 GPF / 6.0 LPF
1/19
© 2019 AS America Inc.
Roughing-in Dimensions
Left or Right Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be a minimum of 6
" (152 mm) above
fixture. Consult Codes for details.
FOR 1-1/2" TOP
SPUD FIXTURES
-C-L-
*CRITICAL
LEVEL
SUPPLY
DN 25 mm
(1" I.P.S.)
108-133 mm
(4-1/4" to 5-1/4")
FINISHED WALL
6047.161
371 mm
(14-5/8")
6047.162
763 mm
(30-1/8")
38mm-127mm
(1-1/2-5")
152 mm
(6
")
(Min.)
292 mm
(11-1/2")
6047.161
686 mm
(27")
6047.162
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND
USABLE BUILDING FACILITIES-CHECK LOCAL CODES