Installation & Assembly

5
MAKE WATER SUPPLY
CONNECTIONS; Fig. 4
D
INSTALL OPTIONAL MIXING
VALVE; Fig. 5
E
Fig. 5
Note: An optional Thermostatic Mixing Valve may be
installed (sold separately) on faucets 705X.1XX &
705X.2XX in addition to Above Deck Mixing valve.
See setup diagram Fig. 5.
Tee fitting is not supplied with Faucet or
Thermostatic Mixing valve and must be purchased
separately. If faucet inlet hoses will not reach water
supplies, longer hoses must be purchased
separately.
For complete detailed installation and operating
instructions, see installations instructions (No.
M968808) supplied with Thermostatic Mixing Valve.
MAINTENANCE
When the Sensor detects a user, the water immediately
starts to flow. Water flow will stop 1.5 seconds after user is
out of sensor range. This Comfort delay allows the user to
comfortably move their hands without the water turning off.
As a precaution, a Safety Timer will turn off the water,
after the sensor has been blocked for 59 seconds.
The water will stay off until the blockage is removed from
the detection zone.
The Comfort and Safety time settings can be adjusted
using the Optional Remote Control (605XRCT).
HAND WASH SENSOR OPERATION;
Fig. 1
A
DETECTION
ZONE
REMOVE PROTECTIVE FILM FROM SENSOR EYE
WHEN INSTALLATION IS COMPLETE.
PROTECTIVE FILM
1. Turn off hot and cold water supplies before
beginning.
2. Place each INLINE FILTER (3) on each wall supply
outlet. Be sure that INLINE FILTER (3) is inserted
in the correct direction. (See Illustration)
3. Connect HOT FLEXIBLE SUPPLY (marked with red
stripe) (1) to INLINE FILTER (3) on hot water control
stop (4). Connect COLD FLEXIBLE SUPPLY
(marked with blue stripe) (2) to INLINE FILTER (3)
on cold water control stop (5). Use adjustable
wrench to tighten connections. Do not over tighten.
4. Faucet supplies are 18" long from faucet base.
Note; If additional supply length is required,
installer must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long,
loop as illustrated to avoid kinking.
Fig. 1
Installation Instructions
Ins tall atio n I n stru c tio n s
(In Toronto Area only: 1-905-3061093)
SELECTRONICâ„¢
Thermostatic Mixing Valve
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: faucetsupport@amstd.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
605XTMV
Specifications
Installation
Adjust Temperature
Service
Replacement Parts
1
2
3
3
4
No. M968808
HOT
SUPPLY
COLD
SUPPLY
TEE
FITTING
Optional Mixing Valve
(Sold Separately)
TEMPERED
WATER SUPPLY
COLD
WATER
M965654 Rev. 2.2 (12/17)
Fig. 4
IMPORTANT: Do not
use sealent on threads
1
2
3
COLD
HOT
(3) INLINE
FILTER
5
4